4.7.2 Removing the Valves

Unscrew the screw glands and remove
1
along with valve plug and seals.
Lift the valve spring and valve out using a
2
hook or a magnetic retriever tool. The valve
can be lifted out by hand.
If removing the seat, a hydraulic valve seat
3
puller appropriate to that particular style of
valve seat should be used to remove the
seat from the bore, exercising care not to
directly strike the valve seat.