Removing The Fluid Modules - Weatherford MP-16 Operation & Maintenance Manual

Triplex pump, two piece fluid end - 5,000 psi
Table of Contents

Advertisement

5.1.3 Removing the Fluid Modules

The fluid cylinder of the MP-16 pump is composed of six separate modules, each of which
may be removed and maintained separately from the others.
Remove the Suction and Discharge
1
manifolds as 5.1.2 and 5.1.1 respectively.
Remove the liners and wear plates as per
2
4.6.1 and 4.6.2 respectively.
Each discharge module is a
weighty piece of equipment
and can cause serious
WARNING
injury if dropped. Be sure
the module is properly
supported before removing
the cap screws.
Unbolt the suction modules from the fluid
3
end. If only one discharge module is to be
accessed, then only the suction module
bolted to it must be removed to remove the
discharge module.
weatherford.com
Pump and Fluid Systems
Chapter 5: Assembly/Disassembly
54
MP-16 2-Piece 5000 psi January 2013