WIKA TR21 Operating Instructions Manual page 10

Miniature resistance thermometer for sanitary applications
Hide thumbs Also See for TR21:
Table of Contents

Advertisement

Available languages

Available languages

3. Specifications
Thermometer with direct sensor output with Pt100 (model TR21-x-ZPx)
and Pt1000 (model TR21-x-ZRx)
Temperature range
Measuring element
EN
Temperature at the connector
Connection method
Tolerance value of the measuring
element per IEC 60751
Response time (per IEC 60751)
Electrical connection
Autoclavability (option)
For detailed specifications for Pt sensors, see Technical information IN 00.17 at www.wika.com.
Case
Material
Ingress protection
Case with connected connector
Coupler connector, not connected
Weight in kg
Ambient conditions
Ambient temperature range
Storage temperature range
Climate class per IEC 60654-1
Maximum permissible humidity per
IEC 60068-2-30 var. 2
Maximum permissible autoclaving
conditions
Shock resistance per IEC 60068-2-27
Salt fog
Readings in % refer to the measuring span
7) Through their small design, face-sensitive measuring resistors serve to reduce the heat dissipation with short insertion
lengths. Available for the temperature range up to 150 °C (302 °F).
For thermowell insertion lengths of less than 50 mm, face-sensitive measuring resistors are recommended.
For thermowell insertion lengths of less than 11 mm, face-sensitive measuring resistors are generally used.
8) Class accuracy AA (1/3 DIN) only valid in the temperature range 0 ...150 °C (32 ... 302 °F)
Class accuracy A only valid in the temperature range -30 ...+150 °C (-22 ... +302 °F) or -30 ...+250 °C (-22 ... +482 °F),
otherwise class B
9) The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress
protection.
10
-50 ... +150 °C (-58 ... +302 °F), -50 ... +250 °C (-58 ... +482 °F)
Pt100 (measuring current: 0.1 ... 1.0 mA)
Face-sensitive Pt100 (measuring current 0.1 ... 1.0 mA)
Pt1000 (measuring current 0.1 ... 0.3 mA)
Face-sensitive Pt1000 (measuring current 0.1 ... 0.3 mA)
max. 85 °C (185 °F)
3-wire
4-wire
Class AA (1/3 DIN)
Class A
8)
t
< 4.7 s
50
M12 x 1 circular connector (4-pin)
Autoclavable with mounted protection cap at connecting plug
(for further details, see „Ambient conditions")
Stainless steel
IP 67 and IP 69 per IEC 60529/EN 60529,
9)
IP 69K per ISO 20653
IP 67 per IEC 60529/EN 60529
approx. 0.3 ... 2.5 (depending on version)
-50 ... +85 °C (-58 ... +185 °F)
-40 ... +85 °C (-40 ... +185 °F)
Cx (-50 ... +85 °C or -58 ... +185 °F, 5 ... 95 % r. h.)
100 % r. h., condensation allowed
max. 134 °C, 3 bar abs., 100 % r. h., duration 20 min.,
max. 50 cycles
50 g, 6 ms, 3 axis, 3 faces, 3 times for each face
IEC 60068-2-11
t
< 12.15 s
90
WIKA operating instructions model TR21