Left Wing; Left Wing Leading Edge; Left Wing Trailing Edge; Before Starting Engine - Cessna U206G STATIONAIR Pilot Operating Handbook

Stationair
Table of Contents

Advertisement

SOLOY TURBINE PAC
POHS CESSNA U/TU 206G
6.

LEFT WING

1.
Main Wheel Tire – CHECK for proper inflation.
2.
Fuel Tank Sump Quick Drain Valves -- DRAIN at least a cupful
of fuel (using sampler cup) to check for water, sediment and
proper fuel grade before each flight of the day and after each
refueling. If water is observed, take further samples until clear
and then gently rock wings and lower tail to the ground to move
any additional contaminants to the sampling points. Take
repeated samples from all fuel drain points until all
contamination has been removed.
3.
Fuel Quantity – CHECK VISUALLY for desired level.
4.
Fuel Filler Cap – SECURE and vent unobstructed.
5.
Fuel Vent Sump Quick-Drain Valve – Drain all fuel from sump
(using sampler cup) before first flight of the day.
7.

LEFT WING Leading Edge

1.
Pitot Tube Cover – REMOVE and check opening for stoppage.
2.
Stall Warning Vane – CHECK for freedom of movement while
master switch is momentarily turned on (horn should sound
when vane is pushed upward).
3.
Wing Tie-Down – DISCONNECT
4.
Fuel Tank Vent – CHECK for blockage.
8.

LEFT WING Trailing Edge

1.
Aileron – CHECK freedom of movement and security.
2.
Flap – CHECK play and security.

BEFORE STARTING ENGINE

1.
Preflight Inspection – COMPLETE
2.
Passenger briefing - COMPLETE
3.
Cabin Doors and Windows – CLOSE and LOCK
4.
Seats, Belts, Shoulder Harnesses – ADJUST and LOCK.
5.
Brakes – TEST and SET
6.
Fuel Selector – ON (BOTH if fuel low warning system installed)
7.
Alternate Air Control – NORM
8.
Fuel Cutoff Control – CUTOFF (OUT)
9.
Propeller Control – IN
10. Power Control – GROUND IDLE
11. All Switches and Circuit Breakers – OFF and SET
12. Avionics – OFF
13. Generator Switch – APU (OFF) POSITION
14. APU – IF AVAILABLE
15. Battery Switch – ON
16. Annunciator Panel and Warning Lights – AUTO FEATHER, OIL
PRESS LOW and GEN OFF BUS lights ON, PRESS-TO-TEST
remaining lights.
17. Fuel Totalizer – CHECK and SET