DETECTION/IGNITION
ELECTRODE
Cable colours
C = Light blue
M = Brown
N = Black
R = Red
G/V = Yellow/Green
B = White
V = Green
INSTRUCTIONS FOR FITTERS
1.24 F - 1.14 F
AMB. THERM./REMOTE CONTR
31
THERMOSTAT
TERMINAL BLOCK M2
PUMP
FAN
EXTERNAL
HYDRAULIC
PROBE
PRESSURE SWITCH
SAFETY
THERMOSTAT
AIR PRESSURE SWITCH
CH NTC SENSOR