CHECKING PROCEDURE
COMPONENT
*
Stator coil
*
Pulsar coil
*
Ignition coil
*
Relay Starter
*
Starter motor
MEASURING INSTRUMENT
*
Multimeter
CHECKING PROCEDURE
STATOR COIL
*
SPECIF/CATION
Resistance 0.8 to 1.0 ohm between each
wire.
*
CHECKING PROCEDURE
Set the multimeter in resistance mode.
Check the Resistance between wires
a. Yellow 1 to
y_
ellow 2
b. Yellow 2 to yellow 3
c. Yellow 3 to yellow 1
CHECKING PROCEDURE
PULSAR COIL
*
*
SPECIFICATION
Resistance 190 to 220 ohm.
CHECKING PROCEDURE
Set the multimeter in resistance
mode.
Check the Resistance between
a. Green/white to white wire.
CHECKING PROCEDURE
IGNITION COIL
*
SPECIFICATION
Resistance
a. Between Brown to Red/white 4 to 5 ohm.
b. Between Brown to HT lead 13 to 17 Kilo
ohm.