Installation
3

Control Box Connections

A
Make the IR sensor, LED, overflow, and
low soap connections as shown.
Connections are NOT
interchangeable.
4

Soap Fill Tube Connection

A
Thread the fill tube assembly (clockwise)
onto the shank.
B
Align the slip joint connector to the I.D. of
the soap tank opening.
C
With the slip joint washer in place, slide
the soap tank nut down until it makes
contact the with soap tank opening.
D
Thread the soap tank nut clockwise onto
the soap tank. Fasten hand tight.
The slip joint connector has up to 5"
of vertical adjustment.
Bradley • P20-224 Rev. A: ECO 19-15-015A
Verge
IR Sensor Connection from
Soap Spout Assembly
Control Box
Fill Tube
Assembly
Slip Joint
Connector
Soap Tank
Nut
Slip Joint
Washer
Soap Tank
Opening
2/10/2020
Deck-Mounted Soap Dispensers
®
Overflow Sensor
Connection from
Soap Tank Assembly
Low Soap Sensor
Connection from Soap
Tank Assembly
LED Connection
from Soap
Spout Assembly
Shank