Maytag MAT20CSAGW Installation Instructions Manual page 17

Commercial washer
Table of Contents

Advertisement

Available languages

Available languages

ELECTRONIC CONTROLS SET-UP INSTRUCTIONS
Control Set-Up Procedures
IMPORTANT: Read all instructions before operating.
The top three key pads on the left side, the top key pad on the
right side, and the digital display are used to set up the controls.
The display can contain 4 numbers and/or letters and a decimal
point. These are used to indicate the set-up codes and related
code values available for use in programming the washer.
How to use the key pads to program the controls
1. The POWERWASH key pad is used to adjust the values
associated with set-up codes. Pressing the key pad will
increment the value.
Rapid adjustment is possible by holding the key pad down.
2. The NORMAL key pad will advance you through the
set-up codes. Pressing the key pad will advance you to
the next available set-up code. Holding the key pad down
will automatically advance through the set-up codes at a rate
of one (1) per second.
3. The DELICATES key pad is used to select or deselect options.
4. The TEMPERATURE key pad is used to decrease set-up code
value.
Start Operating Setup
PD Models: Insert access door key, turn, and lift to remove
n
access door.
PR models set for free vend: Refer to bottom of page 17
n
for entering operating setup.
IMPORTANT: The console must not be opened unless power
is first removed from the washer. To access connector AA1:
g Unplug washer or disconnect power.
g Open console, disconnect plug on AA1, close console.
g Plug in washer or reconnect power.
The washer is now in the set-up mode.
Before proceeding, it is worth noting that, despite all of the
options available, an owner can simply choose to uncrate a new
commercial washer, hook it up, plug it in, and have a unit that
operates.
Set-Up Codes
The NORMAL key pad will advance from code to code.
n
The POWERWASH key pad will increase the code value.
n
The DELICATES key pad will select or deselect options.
n
The TEMPERATURE key pad will decrease the code value.
n
The set-up code is indicated by the one or two left-hand
characters. The set-up code value is indicated by the two
or three right-hand characters.
CODE
6.07
DELICATES Regular Cycle Vend Price - Increase or decrease
DELICATES
between 0 and 200 by pressing the POWERWASH or
TEMPERATURE key pad. Factory preset for 7 coins = $1.75.
6.07
NORMAL ECO Regular Cycle Vend Price - Increase or
NORMAL
decrease between 0 and 200 by pressing the POWERWASH
ECO
or TEMPERATURE key pad. Factory preset for 7 coins = $1.75.
6.07
POWERWASH Regular Cycle Vend Price - Increase or
POWERWASH
decrease between 0 and 200 by pressing the POWERWASH or
TEMPERATURE key pad. Factory preset for 7 coins = $1.75.
6.08
NORMAL Regular Cycle Vend Price - Increase or decrease
NORMAL
between 0 and 200 by pressing the POWERWASH or
TEMPERATURE key pad. Factory preset for 8 coins = $2.00.
g Press the NORMAL key pad once to advance to next code.
ADDITIONAL WASH TIME
7.00
7.00
This is the number of minutes that can be added to a Wash Cycle.
Choose from 00-05 minutes by pressing the POWERWASH
key pad.
g Press the NORMAL key pad once to advance to next code.
ADDITIONAL RINSE TIME
8.00
8.00
This is the number of minutes that can be added to a RINSE
Cycle. Choose from 00-05 minutes by pressing the POWERWASH
key pad.
g Press the NORMAL key pad once to advance to next code.
9.00
CYCLE COUNTER OPTION
This option is either SELECTED 'ON' or NOT SELECTED 'OFF'.
9.00
Not Selected 'OFF'.
9.0C
Selected 'ON' and not able to be deselected.
Press the DELICATES key pad 3 consecutive times to select 'ON'.
Once selected 'ON' it cannot be deselected.
g Press the NORMAL key pad once to advance to next code.
1.00
MONEY COUNTER OPTION
This option is either SELECTED 'ON' or NOT SELECTED 'OFF'.
1.00
Not Selected 'OFF'.
1.0C
Selected 'ON'.
Press the DELICATES key pad 3 consecutive times to select 'ON'
and 3 consecutive times to remove (Not Selected 'OFF'.) Counter
resets by going from 'OFF' to 'ON'.
1.C0
Selected 'ON' and not able to be deselected.
To select 'ON' and not able to be deselected, first select 'ON',
then within 2 seconds press the DELICATES key pad twice,
the POWERWASH key pad once, and exit the set-up mode.
g Press the NORMAL key pad once to advance to next code.
2.00
SPECIAL PRICING OPTION
This option is either SELECTED 'ON' or NOT SELECTED 'OFF'.
2.00
Not Selected 'OFF'.
2.SP
Selected 'ON'. Press the DELICATES key pad once for this
selection.
If SPECIAL PRICING OPTION is selected, there is access to codes '3.'
through '9.'.
NOTE: An external battery needs to be added to keep the clock running during
periods of power outages.
g Press the NORMAL key pad once to advance to next code.
EXPLANATION
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mat20mnagwMat20pdagwMat20pnagw

Table of Contents