2.6

Extension cable

When using an extension cable, make sure it has an adequate conductor cross
section:
• 2.5 mm
up to 50 m in length or
2
• 4 mm
up to 100 m in length.
2
NOTICE
Danger of overheating in the extension cable!
The extension cable may be used only when it has been completely unwound and
stretched out.
2.7

Opening the device

WARNING!
Electric shock from live parts! Danger of death!
• Never open the FRIAMAT fusion unit when it is supplied with operating voltage!
• FRIAMAT fusion units may be opened only by specialised personnel from an
authorised Aliaxis Deutschland service station!
2.8

Safety measures at the installation site

The connecting and fusion cables must be protected against sharp edges.
Do not expose the FRIAMAT fusion unit to heavy mechanical loads. FRIAMAT
fusion units are splash proof. They may not, however, be immersed in water.
2.9

Emergency

In emergencies, immediately set the main switch to OFF, and disconnect the
FRIAMAT fusion unit from the voltage supply.