Error Messages / Warnings / Info - Aliaxis FRIATEC FRIAMAT basic 7th generation Operating Instruction

Table of Contents

Advertisement

8.

Error messages / warnings / info

Irregularities during fusion cause error messages or warnings to appear on the
display of the FRIAMAT fusion unit.
INFORMATION
On the FRIAMAT basic, press the function key to view the displayed error
message in plain text!
INFORMATION
Should the FRIAMAT fusion unit output an error message or warning that is
not listed in the following and that cannot be explained or remedied despite
the plaintext description, contact our service hotline +49 (0)621 486-1533!
No.
Displayed text
02
Temperature
out of range
03
Resistance outside
of tolerance
04
Fitting's wire turn
short circuited
05
Fitting's wire turn
interrupted
28
Meaning/causes
Ambient temperature
outside of permitted range.
Fitting's electrical resistance
outside of tolerance.
Short circuit in the fitting's
wire turn.
Current flow interrupted.
Remedy
You may have to tent over
or shield the fusion area.
Check that contacts sit
firmly and are clean.
If necessary, clean contacts
and replace the fitting.
Replace fitting, and send it
in for analysis.
Check the connection
between the fusion plug and
the fitting. If OK, replace
fitting, and send it in for
analysis.