Technical Details - Aliaxis FRIATEC FRIAMAT basic 7th generation Operating Instruction

Table of Contents

Advertisement

3.14

Technical details

Technical details *
Input voltage range
Frequency range
Input current
Power
Generator rated output
for fittings
d 20 – d 160
d 180 – d 900
Unit fuse
Housing
Connecting cable
Fusion cable
Barcode type
Operating
temperature range**
Fusion current monitoring
Fusion voltage
Service port
Languages
Dimensions W x D x H
Weight
Accessories
Overvoltage classification
Certificate/quality
*: Specifications subject to change.
**: Fusion work on fittings from other manufacturers must comply with their respective working temperature ranges!!
16
FRIAMAT basic
AC 190 V – 250 V
44 Hz...66 Hz
AC 16 A max.
~ AC 2,4 kW
~ AC 5,0 kW
16 A slow blow
international protection IP 54 DIN EN 60529
protection class I DIN EN 60335-1
5 m with contoured plug
4 m with fittings plug, ø 4 mm
code 2/5 interleaved according to ANSI HM 10.8
M-1983 and ISO CD 13950
code 128 a/b/c
2D-code (QR; Aztec; Data Matrix)
according to ISO 12176-5 (Draft)
-20°C...+50°C**
short circuit 110 A
short circuit 1.70 x IN
interrupt 0.25 x IN
max. DC 48V
Bulgarian, Croatian, Czech, Danish, Dutch,
English, Estonian, Finnish, French, German,
Hungarian, Italian, Latvian, Lithuanian, Polish,
Portuguese, Romanian, Russian, Slovakian,
Slovenian, Spanish, Swedish, Turkish
260 x 500 x 340 mm
approx. 12,8 kg
operating instructions, transport box
CE, ISO 9001, WEEE-Reg.-No. DE 49130851,
RoHS, REACH
3,5 kW
USB
Category II