Temperature
sensor fault
34
Temperature limit
reached
70
Communication
fault
Displayed text
Attention!
Double fusion!
Defect / incorrect
barcode
Let the device
cool down.
Fusion stop
End of fusion
Checks
Voltage ... V;
frequency ... Hz
Maintenance
date exceeded
FRIAMAT
preCHECK
deactivated
30
One of the temperature
sensors defective in the
device
A temperature sensor
signals high heating levels in
the device
Data transfer has been dis-
rupted inside the device.
Message is displayed when a fitting has been tried to fuse once
again. Nevertheless, if you intend double fusion on a fitting, you
must disconnect the fusion unit's pins from the fitting after the
first fusion, and let it cool down (see the processing instructions
issued by the fitting manufacturer).
Use a new barcode on an identical fitting, or correct the
entered code manually.
Protective function that prevents the device from overheating.
Let the device cool down. The fans reduce the temperature of
the device when it is switched ON.
Fusion stopped at STOP key.
Fusion finished.
Checks on the fitting data and FRIAMAT preCHECK function.
Adjust generator, and acknowledge at STOP key.
Have the device serviced by Aliaxis Deutschland GmbH or
an authorised service station.
When the 2D barcode complying with ISO 12176-5 (Draft) is
applied with multiphase fusions, the FRIAMAT preCHECK
function is activated
Contact the Aliaxis
Deutschland service hotline:
+49 (0) 621 - 486 1533
Contact the Aliaxis
Deutschland service hotline:
+49 (0) 621 - 486 1533
Contact the Aliaxis
Deutschland service hotline:
+49 (0) 621 - 486 1533
Tip / remedy