Aliaxis FRIATEC FRIAMAT basic 7th generation Operating Instruction page 22

Table of Contents

Advertisement

NOTICE
Do not connect any other consumers during fusion!
You can stop the fusion procedure at any time by pressing the STOP key.
Fusion can be resumed after the fusion joint has cooled completely (and all
causes of the fault have been eliminated). Observe here the processing
instructions from the fitting manufacturer.
INFORMATION
When an acoustic signal is not emitted confirming the read-in process, examine
the wand or barcode scanner for soiling or damage. If necessary, you can also
perform the fusion in emergency input mode (see Sections 5.3 and 6.3)!
Operating step
1. "Pipe Processed?" appears on the display. When applicable, confirm this
with the (START) or the (Next) function key.
2. The fitting data then appear again. These must be checked and confirmed
by the user.
3. Press the (START) key to initiate the fusion procedure. The ambient temper-
ature is measured, and the resistance of the connected fitting determined
("Check" appears on the display). The connected fitting and the FRIAMAT
preCHECK function are now checked. On positive results, fusion starts
automatically. The display shows the fusion progress. This shows in
seconds the duration of fusion and the fusion time left.
4. "Fusion successful" on the display means: Fusion procedure has ended.
"Fusion time nom" and "Fusion time act" mean nominal and actual fusion
time and must agree.
5. Note the fusion parameters on the pipe/fitting. This also serves to prevent
double fusions.
6. "Fusion successful" with "Fusion time nom" and "Fusion time act" must
always be acknowledged with OK or, alternatively, with the START or STOP
key. The fusion procedure has ended, and the FRIAMAT fusion unit is ready
for the next fusion.