RS232 Communication

RS232 control is not necessary for operation, but is a convenient way to control Planar
UltraRes X™ Series displays from a computer at a distance. Most things you can do with the
remote, you can do with RS232 commands. Plus, you can send inquiries to the displays and
find out the current settings and values. RS232 connections are made with standard straight-
through cables.
Note: Serial communication can occur over RS232, USB-B or LAN.
1.

Applicable Models

This RS-232 user manual applies to all Planar UltraRes X Series models with the exception of
the UR8450 and UR9850 models. The RS232 instructions for the UR8450 and UR9850 models
can be found in the User Manual for these models, located at www.planar.com/support/.
2.

RS232 Setup

The use of RS232 requires the display's Power Down Mode to be in Networked Standby or
Fast Startup. See the "Power Down Mode" section of the Planar UltraRes X Series User
Manual.
The RS232 connection must use the following settings:
19200 baud rate
8 data bits
1 stop bit
No parity bit
No HW (RTS/CTS) or SW (XON/XOFF) flow control