Then, set Parameter PA (see "Parameters menu") as follows:
Conversion from METHANE to LPG
Parameter
PA
Conversion from LPG to METHANE
Parameter
PA
b
Once the gas type has been switched, check that all of the gas
parts are properly sealed.

3 11 Adjustments

b
Adjustments to the maximum, minimum and slow ignition values
must only be made by qualified technicians.
The boiler has already been factory set by the manufacturer.
If it is necessary to adjust it again, for example after extraordinary main-
tenance, after replacement of gas valve or after gas conversion, carry out
the following procedure.
- Unscrew the pressure tube screw (A - Fig. 25) on the gas valve and
connect the pressure gauge.
See Fig. 25
- Perform a DHW request.
- Read the pressure values on the pressure gauge and check that they
comply with the indications in the table.
If necessary correct these values as follows:
- access the technician menu as detailed in "Parameters menu"
- set the parameters PH, PL and Pd until the values in mbar indicated
below are obtained
Models 11
Parameter
G20
G30
mbar
mbar
PH
11,5
27
PL
1,8
6,2
Pd
5,5
13,5
- Stop DHW request.
- Remove the pressure gauge and fix the screw.
16
Value
Models 11
Models 14
04 LPG
08 LPG
Value
Models 11
Models 14
03 NG
07 NG
Default values
Models 14
G31
G20
G30
mbar
mbar
mbar
33,5
11,6
26,5
6,9
1,5
4,5
13,7
6,2
9,1

4 PUTTING INTO SERVICE

4 1 Controls interface

A
B
Battery charge LED
A
B
ON/OFF and CON-
FIRM button
+ key
C
- and RESET button
D
Battery charge LED
The LED flashes when the battery is low, indicating that the batteries need
replacing.
ON/OFF and CONFIRM button
Use this button to turn the appliance on and off. Use this button to confirm
your choice.
+ key
Use the + button to navigate through the available parameters, change
the value of a given parameter and increase the temperature set for do-
mestic hot water.
G31
- and RESET button
Use the - button to navigate through the available parameters, change
mbar
the value of a given parameter and decrease the temperature set for do-
34,4
mestic hot water.
4,9
Press and hold the RESET button for 5 seconds to reset a fault.
13,7
+ and - keys pressed together
To access menu parameters (see paragraph "Parameters menu").

4 2 Description of icons

temperature measure unit
Flame detected
Battery charged
Low battery

4 3 Operation

b
The first commissioning of the appliance must be carried out by
qualified personnel.
Hot water heaters are gas appliances that produce instant hot water. Hot
water can be distributed from one or more taps.
When there is a request for hot water (i.e. when a tap is turned on), the
main burner switches on and the heater heats the water inside it.
The gas flow is varied by means of a thermostatic device which controls
the set water temperature. The set value for this device can itself be set.
This appliance is equipped with an electronic board powered by 2 x 1.5
V D-type batteries which automatically switch on the pilot flame and then
the burner every time hot water is requested.
The board ensures that the appliance has been switched on and detects
the flame via ionisation.
7
C
D
To access menu pa-
C+D
rameters
Fig. 1