Download Print this page

Safety Notes; Installation Instructions; Symbol Description - Hans Grohe PuraVida 15672007 Instructions For Use/Assembly Instructions

Advertisement

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms!
• The plumbing codes applicable in the respective
countries must be oberserved.
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Instantaneous heater didn't work
max. 1,6 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
150 ±15 mm
cold right - hot left
max. 70°C / 4 min
Cause
- Shower filter seal dirty
- check valve hasn't moved back
- Cartridge defective, calcified
- Cartridge defective
- Flow limiter in handshower isn't
removed
- Filters are dirty
- check valve hasn't moved back
Assembly (see page 4)
English

Symbol description

Do not use silicone containing acetic acid!
Maintenance (see page 11)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Dimensions (see page 6)
Flow diagram (see page 7)
Spare parts (see page 13)
Operation (see page 5)
Cleaning (see page 8)
Remedy
- Clean filter seal between shower
and hose
- Exchange check valves
- Exchange cartridge
- Exchange cartridge
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange check valves
3

Advertisement

loading

This manual is also suitable for:

Puravida 15672407Puravida 15472007Puravida 15472407