Connecting the Failsafe Alarm Relay

The failsafe relay can be configured to latch based on alarm conditions. The NO
(Normally Open) contact is closed when the unit is powered and there are no active
alarms. If the device is not powered or if an active alarm is configured, the relay
opens the NO contact and closes the NC (Normally Closed) contact.
Note
Control of the failsafe relay output is configurable through RUGGEDCOM RS900G .
One common application for this relay is to signal an alarm if a power failure
occurs. For more information, refer to the RUGGEDCOM RS900G User Guide for the
RUGGEDCOM RS900G.
The following shows the proper relay connections.
1
2
3
Figure 2.5
2.6

Connecting Power

The RUGGEDCOM RS900G features an integrated high AC/DC or low DC power supply
that accepts input from redudant power sources.
Note
Power sources can be connected to either power supply terminal block on the device.
IMPORTANT
RUGGEDCOM RS900G
Installation Manual, 01/2021, C79000-G8976-1025-08
Using two #6-32 screws for each adapter, secure the device to the panel.
1
2
3
Normally Closed
Common
Normally Open
Failsafe Alarm Relay Wiring
For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker
must be installed.
Installing the Device
2.5 Connecting the Failsafe Alarm Relay
11