■ Analog output
This instrument can be connected to Pen recorders, Vidi-light recorder, Oscilloscopes, Voltmeters, etc.
When using with these products, please refer to the appropriate operation manuals.
■ Inspection and calibration
The detecting element of the HIOS Digital Torque Meter has a specially designed structure and
maintains its stabilized load accuracy over a long period of time. However at least once a year
inspections are required to get the best use from the Meter. Calibration can be practiced by customers
using a weight and weight hanging disk (optionally available) to be attached to the Joint Shaft while the
Detector is horizontally held by a clamp. When a stabilized and correct state cannot be achieved by
the customer, adjustment and repair will be carried out by local authorized distributors. When the jam
is found exceeding local technical ability, the Meter will be repaired by the manufacturer.
■ Attention
The product that you have purchased contains a rechargeable battery. The battery is recyclable. At the
end of it's useful life, under various state and local laws, it may be illegal to dispose of this battery into
the municipal waste stream.
Check with your local solid waste officials for details in your area for recycling options or proper
disposal.
■ Caution
Never apply more torque than the tolerance level given in the specifications, as this could damage
the instrument.
Do not strike the plastic display panel or place heavy objects on it.
Because torque meters are sensitive to ambient conditions, it is necessary to occasionally perform
zero adjustment.
Take care to shield the instrument from exposure to water, oil or other liquids, vibration, dust,
hot air, indoor or outdoor electrical noise, high humidity (operating humidity range is 35-65%),
temperature extremes (operating temperature range is 15℃ - 40℃ ) and all other conditions that
could harm the instrument or impair its functioning.
Do not remove the back panel for calibration, etc.
Refrain from rough usage or dropping of the instrument.
Do not store in places subject to high humidity or extreme drops in humidity that could result in
harmful condensation inside the instrument.
Please note that the display and detector units of your HIT Digital Torque Meter each have the
same serial number because they are calibrated together and are meant to be used together.