Download Print this page

HIOS HIT Series Owner's Manual page 5

Impact torque meters

Advertisement

5. When using a printer set the mode switch to "Peak." When peak measurement is desired, set the
Mode Switch at PEAK. The peak value is held for more than 5 seconds when more than 15 digits
signals are inputted. It can be cancelled by pushing the reset button. (There are reset buttons on
the display and the detector unit.)
6. See "Setting torque level signal tone" below to set the signal tone to sound when the desired
torque level is reached.
7. When you are finished measuring, turn off the power switch and remove the driver, etc. from the
socket.
■ How to set the buzz set
1. Turn the zero adjustment knob until the desired torque value is displayed.
2. Turning the buzz set volume control to the left causes the signal to sound, then stop turning.
3. Turn the zero adjustment knob until the displayed value reads zero. (Note that the set value is not
displayed, so it may be helpful to make a written note of it.)
4. If the mode switch is set to track mode, the buzz will sound at the preset value. This can be turned
off by removing the load to return the display to zero.
5. In peak measurement, when the preset load is reached, the buzz will stop and the value will freeze
on the peak value. The display can be returned to zero by pressing the reset button.
6. To terminate the buzz set, turn the volume control all the way to the right. When not using the
signal tone, keep the volume control set turned all the way to the right.
■ Recharging
Turn the power switch off before recharging, using the recharging unit. A full recharge takes less than
8 hours.
(Caution)
• Never recharge for more than 8 hours.
• Do not use the recharging unit for recharging anything but HIT Digital Torque Meters.
• Do not use the instrument during recharging.
■ Type of data output
Use the Mitutoyo Input Tool (available for purchase from many dealers) to transfer measurement data
to a computer.
Measured data input unit input tool (USB keyboard conversion type)
Model: No. IT-016U
* Uses Mitsutoyo Connection cable, No. 06AGF590 2 m (sold separately)
- 5 -

Advertisement

loading

This manual is also suitable for:

Hit-200Hit-500Hit-2000