Warmup HTR-4ROPO Installation Manual

Warmup HTR-4ROPO Installation Manual

Heated towel rail

Advertisement

Quick Links

Heated Towel Rails
Installation Manual
Technical Helpline
0345 345 2288
IMPORTANT!
Please read this manual
before attempting to install
your Warmup product.
Complete and submit your
warranty form online at
www.warmup.co.uk
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HTR-4ROPO and is the answer not in the manual?

Questions and answers

Summary of Contents for Warmup HTR-4ROPO

  • Page 1 Heated Towel Rails Installation Manual Technical Helpline 0345 345 2288 IMPORTANT! Please read this manual before attempting to install your Warmup product. Complete and submit your warranty form online at www.warmup.co.uk...
  • Page 2 The world’s best-selling floor heating brand™ Over 2 million installations in more than 60 countries Experience MyHeating ™ Download now for iOS and Android Unique to Warmup: SmartGeo ™ Smarter geo-fencing. Reduce energy usage by up to 25% ™ EasySwitch...
  • Page 3: Table Of Contents

    Control Card ���������������������������������������������������������������������������18 Technical Specifications ��������������������������������������������������������19 WARNING! Your Warmup® heated towel rail has been designed so that installation is quick and straight forward, but as with all electrical systems, certain procedures must be strictly followed. Warmup plc, accepts no liability, expressed or implied, for any loss or consequential damage suffered as a result of installations which in any way contravene the instructions that follow.
  • Page 4: Components Required For Installation

    Components • HTR-1ROPO • HTR-1SQPO • HTR-1ROBR • HTR-1SQBR • HTR-1ROBL • HTR-1SQBL Additional components needed as part of your Warmup heating installation: 30 mA Residual Current Device (RCD), required as part of all installations. Digital Multi-meter required for testing the resistance of the heated towel rails.
  • Page 5: Do's & Don

    Do’s & Don’ts Install the Warmup Heated Towel Rails in line with these instructions� The towel rail is designed to warm towels only and not provide primary heating� Ensure that the control card at the back of the manual is...
  • Page 6: Step 1 - Electrical Supply

    Zones 0 or 1. Warmup Heated Towel Rails have an IP rating of IP55 and are suitable for installation within Zone 1, Zone 2, Zone 3 or outside of any Zones.
  • Page 7: Step 2 - Layout Planning

    Step 2 - Layout Planning Before you begin In order to avoid a hazard for very young children, heated towel rails should be installed so that the lowest heated rail is at least 600 mm above the floor. IMPORTANT: DO NOT mount towel rails to plasterboard alone as they will not provide enough support.
  • Page 8: Step 3 - Mounting The Rails (Ladder)

    Screws Mount Wall Mount Wall Mount Short screws Hex key Warmup’s Ladder Towel Rails can be installed with either concealed or exposed wiring. The instructions below concentrate on concealed wiring. • Measure and record the • Using a long screwdriver,...
  • Page 9 Step 3 - Mounting the Rail Ladder Rails Attach the final leg (1B or • Install the remaining 2 legs • (1A) to the towel rail body as 1C), for exposed or concealed shown in Step 2. wiring, to the towel rail body using the grub screws (2) as shown.
  • Page 10 Step 3 - Mounting the Rail Ladder Rails • Remove the wall mounts • Drill a larger 4th hole for the x 3 (6) from the legs (1A). concealed wiring leg. • Insert the mounting screws • Remove the concealed wiring (5) through the wall mounts wall mount (7) from the leg and secure to the wall as...
  • Page 12: Mounting The Rails (Single Bar)

    • Also measure the distance • Stop installation immediately between the screw and power and contact Warmup if its supply cable holes. resistance falls outside the values set out in the resistance table.
  • Page 13 Step 3 - Mounting the Rail Single Bar Rails • Mark the screw and power • Drill three holes into the supply cable hole positions on previously marked positions, the wall you intend to mount two for the mounting screws the rail using measurements and one for the supply cable taken in Step 2.
  • Page 14: Step 4 - Make Electrical Connection

    Please see Page 6 for correct zoning. Warmup Heated Towel Rails can be connected into the rooms lighting circuit, enabling the towel rail when the lights are switched on. 30 mA...
  • Page 15: Troubleshooting

    Troubleshooting Instructions which are shaded must completed by a qualified electrician. HEATING ISSUE 1 - The towel rail does not heat up. END USER ELECTRICIAN Are the wiring With the towel connections Rewire the rail switched from the towel towel rail to the on allow 3 - 5 power supply.
  • Page 16: How To Test The Towel Rail

    How to test the heated Towel Rail The heated towel rails must be tested before they are installed and again before final connection is made. The resistance (ohms) of each heater should be measured. You should carry out the following tests and should expect the results detailed below: •...
  • Page 17: Warranty

    This 5 year guarantee applies: 1. Only if the unit is registered with Warmup within 30 days after purchase� Registration can be completed online at www�warmup�co�uk� In the event of a claim, proof of purchase is required, so keep your invoice and receipt - such invoice and receipt should state the exact model that has been purchased;...
  • Page 18: Control Card

    Resistance Date Signed Company stamp/name This form must be completed as part of the Warmup Guarantee. Ensure that the values are as per the instruction manual. This card must be situated close to the consumer unit in a visible place.
  • Page 19: Technical Specifications

    PRODUCT SIZE POWER LOAD +/- 10 % CODE (mm) (Ω) 4 Bar Ladder - Round Polished HTR-4ROPO 0.23 1017 520(h) x 500(l) x 120(d) mm 4 Bar Ladder - Square Polished HTR-4SQPO 0.23 1017 435(h) x 525(l) x 120(d) mm...
  • Page 20 Web: www.warmup.co.uk Email: uk@warmup.com Tel: 0345 345 2288 Fax: 0345 345 2299 The WARMUP word and associated logos are trade marks. © Warmup Plc. 2019 – Regd. TM Nos. 1257724, 4409934, 4409926, 5265707. E & OE. Bathroom www.warmup.co.uk Heating Warmup - IM - HTR - V1.4 2019-06-11...

Table of Contents