Demux Pid Map; Ip Lans; Primary And Secondary Data Ip Lans - Harris SELENIO SEL-MDX1-EES Installation And Operation Manual

Mpeg-2 transport stream multiplexer/demultiplexer
Table of Contents

Advertisement

If the type is set to Off, the corresponding function block and external connector are
disabled.
The type can be set to Copy on even numbered functions blocks where the preceding
function block type is set to Mux. In this case, the corresponding even numbered external
connector will deliver a copy of the output of the preceding odd numbered Mux function
block output.

Demux PID Map

The PID map makes it possible to split multiple program streams into a maximum of 240
programs Each program is remapped according to the PID Table shown in the UI. The
default setting for each PID is -1.
Default PIDs are based on offsets from a base PID of 48. They are:

IP LANs

Primary and Secondary Data IP LANs

The Secondary Data IP LAN settings provided redundancy for the Primary settings. The
backup functions provided by the Secondary Data IP LANs require the installation of a video
IP submodule on the Selenio frame controller. When making settings in the IP LAN table,
ensure that you click the Apply button to save your settings.
In a frame with a second controller (with the data Ethernet switch daughter card) the
MDX module can receive and transmit on redundant primary and secondary IP data
links.
On each physical link, IP interfaces can be configured for untagged network traffic (Vlan
ID = 0) and tagged virtual LAN network traffic (Vlan ID 1 to 4094).
VLAN ID
This parameter sets the entry's VLAN identifier.
A value of 0 indicates that the interface is for untagged network traffic.
A value from 1 to 4094 indicates that the interface is for tagged virtual LAN traffic.
PMT: base + 0 (48)
Video: base + 1 (49)
PCR: base + 2 (50)
8 Audios: base + 3 to base + 10 (51 - 58)
2 Data: base + 11 and base + 12 (59, 60)
ECM: base + 14 (62)
SEL-MDX1
Installation and Operation Manual
Copyright © 2011, Harris Corporation
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Selenio sel-mdx1-ers

Table of Contents