Field Wiring 1

Disconnect Device

Circuit Protection 1

Floor Mounting 1

before installation or in a laboratory or other temporary location, an optional
stability plate is available.
All lines are routed inside the building within a grounded conduit
(recommended ½" diameter terminated by a ¾" Romex connector).
2
Incoming power lines are type TN-C with three conductors (hot, neutral and
ground).
3
All field wiring shall be in accordance with the National Electrical Code (NEC).
A readily accessible disconnect device shall be incorporated into the building
installation wiring.
Circuit Type: Branch Circuit Protection
2
Input Voltage: 120 - 240V AC, 50 - 60 Hz
3
Max Current: 2A - Single-Sided and Wall Mount
4A - Dual-Sided
Anchor bolts provided are intended for concrete. Concrete flooring must meet
commercial building standards. Verify for your local State building code.
2
Mark the floor corresponding to the anchor slots on the kiosk.
3
Drill 3/8" anchor bolt holes (4 minimum) to support anchor bolts into the floor
at least 4"-5" deep.
4
Install anchors into floor and verify that they are tight and have not damaged
the floor.