Advertisement

November 2020
5. The certification of the level switch relies upon the following
materials used in its construction:
6. It is the responsibility of the user to ensure:
7. Cleaning-In-Place (CIP) routines up to 160 °F (71 °C) are suitable for
the level switch.
8. Steaming-In-Place (SIP) routines up to 302 °F (150 °C) are suitable for
the level switch.
Quick Start Guide
a. Product contact surfaces
Probe:
b. Non-product contact surfaces
Enclosure:
Lens:
Seals:
Connector:
a. The materials listed in instruction
and cleaning (sanitisation) processes.
b. The installation of the level switch is drainable and cleanable.
c. That the joint requirements between the probe and the
vessel/pipe are compatible with the process media,
applicable standards, and code of practice. In EHEDG
applications, the seals (gaskets) used should be as defined in
the EHEDG position paper "Easy cleanable pipe couplings and
process connections".
Stainless steel 316/316L
Stainless steel 304 type
Nylon 12
Nitrile rubber
Nylon (PA6)
5
are suitable for the media
Quick Start Guide