Quick Start Guide
5.6
Instructions for hygienic installations
The following instructions are for a Rosemount
switch") with a 51 mm Tri Clamp fitting covered by 3-A authorization 3632
and EHEDG certificate 102016, and ASME-BPE and FDA compliance:
1. The level switch is suitable for installation on pipeline (with fork gap
in line with the flow) and on closed vessels (with the fork gap
vertical).
EHEDG only recommend horizontal stub mounting in pipelines:
2. Installation of this equipment shall be carried out by suitably trained
personnel, in accordance with the applicable code of practice.
3. Inspection and maintenance of this equipment shall be carried out by
suitably trained personnel, in accordance with the applicable code of
practice.
4. If the level switch is installed in a stub then, to ensure clean-ability,
the length (L) must not exceed the diameter (D) with a minimum
diameter (D) of 46 mm.