Huawei NE40E-M2 Series Hardware Description page 34

Universal service router
Table of Contents

Advertisement

Figure 5-2 Appearance
Table 5-3 Description of the indicators on the DC power module
Component
OUT
IN
Technical Specifications
Item
Dimensions (H x D x W)
Issue ()
The DC power monitoring channel can implement real-time monitoring on power supply.
In addition, the DC power monitoring channel allows you to query the manufacturing ID,
input voltage, and temperature of the power supply modules in real time, and supports
real-time reporting of power supply alarms.
You do not need to connect protection ground cables to the power supply modules, but
the protection ground cable for the chassis must be properly grounded. DC power cables
include a -48 V power cable and an RTN ground cable. The required cable length
depends on the distance between the cabinet and the power distribution cabinet for the
device. The DC power cables need to be prepared according to the required lengths on
site.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Status
When the indicator is steady green, the
power supply modules work normally and
provide stable power.
When the indicator is steady red, the power
supply modules encounter hardware faults,
no -48 V or -60 V power input, or
under-voltage or over-voltage.
When the indicator is off, the power supply
modules are powered off or the hardware of
the power supply modules is faulty.
When the indicator is steady green, the
power input is normal.
When the indicator is off, there is no -48 V
or -60 V power input.
Specification
19.8mm x 211.8mm x 96.5mm (0.77 in. x 8.33 in. x 3.79
in.)
5 Power
32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne40e-m2eNe40e-m2fNe40e-m2hV800r010c00

Table of Contents