Item
Redundant NPUs
Redundant fans
Redundant power supply
Forwarding performance
Switching capacity
Operating temperature
Storage temperature
Relative operating humidity
Relative storage humidity
Long-term operating altitude
Storage altitude
4.2 NE40E-M2F
Overview
Table 4-6 Device attributes
Product Type
NE40E-M2F
Issue ()
Specification
Integrated
The device can work properly for a short time at 40º C
if a single fan fails.
1+1
70 Mpps
80 Gbps
-40 ° C to 70 ° C (-40° F to 158° F)
5% to 95% RH, non-condensing
3000m @ 40° C
Lower than 5000 m (16404 ft)
Description
BOM
NE40E-M2F
02350BUR
Integrated
Chassis
Components
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Long-term:DC: -5 ° C to 65 ° C (23° F to 149° F)
AC: 0 ° C to 45 ° C (32° F to 113° F)
Short-term:AC: -5 ° C to 55 ° C (23° F to 131° F)
Remark:Restriction on the temperature variation
rate: 30 ° C/hour
Long-term:5% to 85% RH, non-condensing
Short-term:5% to 95% RH, non-condensing
Model
CR5B0BKP037
2
4 Chassis
Earliest
Software
Version
V800R007C00
18