Clear Display and Fill 3.7.3.2 Setting a Point 3.7.3.3 Reading Out a Point from the Display 3.7.3.4 Drawing a Rectangle Page 2 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Page 3
APPENDIX Standard Equipment Optional Accessories Order Numbers Displayable Characters Maintenance and Care Declaration of Conformity Warranty / Liability Versions Overview Page 3 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
(resolution in pixels). Graphics, texts and variables to be displayed must properly fit into the display unit. Page 6 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
8 lines are simply not visible at a module with 8 pixel lines. The following example depicts a module with 64 x 16 pixels including three different character heights: Page 8 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
The display unit then waits for valid output data from the user (via the serial or the parallel interface). Page 9 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
LEN-H und LEN-L only need to be transmitted if a checksum is used. If bit 1 in the FC byte is not set, LEN-H and LEN-L may not be transmitted! Page 11 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
4 through 7 must be set (1) CHK-L: Low nibble for checksum: bits 3 through 0, bits 4 through 7 must be set (1). Page 12 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
After power up, the display needs approx. 3 seconds more time (because of synchronization). At querying graphics, the coding of the graphic number can be three-digit or four-digit. Page 13 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
... must be transmitted for position 123 (ASCII characters “1”, “2” and “3.”) Refer to chapter “Displayable Characters” for a table of displayable ASCII characters! Page 15 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Existing character sets are overwritten with the new character sets if a new configuration is uploaded to the display unit! Page 16 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
(from the last “ESC-A” frame)! Black is used if the background colour has been set to transparent! Page 18 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Variable content is stored to RAM only. After the device has been switched off and back on again, the variables are returned to their pre- configured values. Page 19 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Variable positioning is stored to RAM only. After the device has been switched off and back on again, the variables are returned to their pre- configured positions. Page 20 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Decimal Decimal Decimal Value 10000s Value 1000s Value 100s Value 10s Value 1s „+“, „-“ „0“-„9“ „0“-„9“ „0“-„9“ „0“-„9“ „0“-„9“ Page 21 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Page 22
If the current value is not in the range „MIN-border ... MAX-border“ then a blinking mark will be shown at the MIN- or MAX-border. Page 22 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Page 23
The background colour used for variables may not be transparent, and a character set with uniform character width should be used in order to assure correct display. Page 23 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
“0” – “9” The perimeter of the rectangle is drawn with the foreground colour. The rectangle is filled with the background colour. Page 25 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
(end line > start line!). Only the last select- ed scrolling range is used! Page 26 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Scrolling range with start line = 50, end line = 80 1. scrolling range: line 50 to 63 2. scrolling range: line 64 to 80 Page 27 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
“2” = red. The transmitted value is multiplied in accordance with the HEX switch settings at the device before it is applied. Page 28 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
The output bits are used to switch the digital outputs (if included). After switching the device on, all outputs are cleared (0). Page 29 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Execution starts with the indicated macro. Skipping is also possible during macro execution through the use of this command within a macro sequence. Page 30 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
100 ms happens and the digital inputs are read in again. Page 31 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Page 32
100 ms), for example during the delay time (1 second). If Input 2 is set, the display is cleared. Page 32 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
This sequence can be used as part of a macro, as well as part of a re- ceive message. 3.7.6.4 Stop Macro Execution Byte 1 Byte 2 Function “E” Page 33 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
(“reading out decimal point from the display”, “digital inputs and outputs”). The error code in the response frame always relates to the last partition frame. Page 34 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
=> An “online text” with character set 1, on cursor position x=2, y=3 with foreground colour „yellow“ and background colour „black“ is displayed (blinking). Page 35 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
The character “A” is to be displayed at the MIGRA at address 1: Master: 02 81 80 83 F0 F1 41 FA F6 03 Migra: 02 80 81 80 30 03 Page 36 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
3.11.2 Input Level at the Parallel Inputs Level Voltage Range U (low) + 0 to 1.6 V DC U (high) + 18 to 30 V DC Page 37 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Strobe (rising edge, 0 to 1: apply value now) For example, the following assignments are used to display text 12: 16 15 14 13 12 11 10 Page 38 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Strobe (rising edge, 0 to 1: apply value now) For example, the following assignments are used to clear graphic 7: 16 15 14 13 12 11 10 Page 39 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
The bus termination can also be set internally, when required (see chapter “Internal Switches”). The bus termination may be set only either internally or externally. Page 41 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Page 42
Relay 2, normally open, b n.c. Relay 1 / 2 is controlled by digital output 1 / 2 (frame: ESC+“D”). Page 42 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Page 43
Please refer to chapter “Parallel Interface” for details concerning the parallel inputs. Page 43 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Stop bits: The device must be reset if these parameters are changed! (Switch the device off and back on again.) Page 44 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Page 45
High environment brightness is necessary to obtain a control value of 100 %. Most right position: Low environment brightness is necessary to obtain a control value of 100 %. Page 45 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
Page 46
However, does not function with RS 485 and Windows PC software (because timing for RTS direction changes is inaccu- rate due to Windows limitations). Page 46 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
A jumper is included on the PCB (ST8). The display unit can be manual- ly set to the boot mode with this jumper (jumper may not be connected for normal operation). Page 47 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
*Carriage Return: The cursor jumps to the beginning of the next line. Any Windows character set, as well as any user defined character set, can be used. Page 49 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
“as is”. No guarantee claims may be made in such cases. The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well. Page 52 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de...