microSYST migan User Manual

microSYST migan User Manual

Large format numeric led display with ethernet ip interface

Advertisement

Quick Links

migan Ethernet IP
Large Format Numeric LED Display with Ethernet IP Interface

User manual

microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
 +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the migan and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for microSYST migan

  • Page 1: User Manual

    Ethernet IP Large Format Numeric LED Display with Ethernet IP Interface User manual microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 2: Control Data

    Response Frame (from Display) APPENDIX Displayable Characters Ethernet IP Diagnostics Factory Settings General Notes Declaration of Conformity Warranty / Liability Versions Overview Page 2 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 3: General

    Articulated arm, angle bracket, hanging on chain or mounting frame see chapter “Device Configuration“ Protection: see chapter “Device Configuration“ Operating temp.: Storage temp.: -25 ... +70 °C Page 3 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 4: Device Configuration

    -20...+50 °C (standard) -25...+50 °C (optional with heating) ____________ °C Housing dimensions: _________x_________x_________mm Housing Material: Aluminum profile Stainless steel Sheet metal Page 4 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 5: Connector Pin Assignments

    Please see inside labelling of the mating plugs for pin assignment. Power Connector 230 VAC Assignment (PE) Power Connector 24 VDC (optional) Assignment +24 VDC Connector RS232-HMS Assignment Page 5 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 6: Device Start

     <first 2 digits of the baud rate > <parity> <data bits>  A<display address> Shown parameters refer to the internal interface and are not significant for Ethernet/IP operation. Page 6 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 7: Ethernet Ip Configuration

     Now the interface configuration is completed. You can find the original configuration at our home page www.microsyst.de in the area “Downloads & Support” -> “migan” -> “Ethernet IP” -> “Configuration File for HMS Interface”. Page 7 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach...
  • Page 8 ** only at communication with response frame *Toggle byte: The toggle byte must be increased by 1, if the frame shall be processed Page 8 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 9 A point is set, if corresponding bit = 1 Either a decimal point or a colon can be displays (depending on ordering option). Page 9 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 10 TB 0E 01 0C 00 41 40 00 7B 00 41 40 00 37 02 55 \______________/\______________/ Line 1 Line 2 (O2...D2) (O2...D2) Page 10 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 11: Response Frame (From Display)

    Status of a digital input = 1, if it’s set at the moment. Example Response frame, if digital input 3 is set TB 04 01 02 04 55 Page 11 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 12: Appendix

    “Blank” . / : . / : *Either decimal point or colon can be displays. This depends on ordering option. Page 12 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 13: Ethernet Ip Diagnostics

    LED 3 - Link State Description steady green module has a link steady off module does not sense a link Page 13 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 14 DIP Switch (inside the housing of the module) All DIP switches must be switched off. Page 14 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 15: Factory Settings

    S2 = „0“, S1 = „1“, S3 = „D“, S5-DIP1 = ON, S5-DIP2 = ON Green LED blinks with 2 Hz, if processor is running. Page 15 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 16: General Notes

    / or power line.  Do not attempt to repair the device yourself. Any interference by unauthorized personnel will void the warranty. Page 16 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 17: Eu-Konformitätserklärung

    Richtlinie 2014/35/EU +A2:2013 Low Voltage Directive RoHS Richtlinie 2011/65/EU EN50581:2012 RoHS Directive Windischeschenbach, 20.11.2017 Manuel Raß Geschäftsführer / General Manager Page 17 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 18: Warranty / Liability

    “as is”. No guarantee claims may be made in such cases. The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well. Page 18 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 19: Versions Overview

    4.7 Versions Overview Version Date Remarks, Description 1.00 18.07.16 Document created 1.10 20.11.17 Change of address Certified per DIN EN ISO 9001. Page 19 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...

Table of Contents