For compatibility reasons, however, the “old” controlling can be activated by software (MKS). For details, refer to chapter “Protocol Classic”. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 4...
Operating temp.: Storage temp.: -25 ... +70 °C Details to the used interface can be found in the corresponding chapters. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 5...
Basically, you need the protocols, which are described in chapter “Control Data“. Depending on the interface, there may be additional bytes. Please see respective chapter “Operation“ for details. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 7...
Blinks at a frequency of approx. 0,5 Hz Software upload: Flickers during the upload Configuration: Defective MKS: Blinks with an Error Code: 1x microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 8...
ARP -S XXX.XXX.XXX.XXX xx-xx-xx-xx-xx-xx < CR> XXX.XXX.XXX.XXX : desired IP address xx-xx-xx-xx-xx-xx : Ethernet MAC address of the device (see label at the housing) microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 11...
Page 12
Now, the control frame can be transmitted to the display via the selected IP address (TCP/IP connection via port 10001). microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 12...
Save settings with item "9" (Save and exit) and "Enter". Close the window of the MS DOS entry prompt microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 14...
The configured input data width must be at least 2 bytes larger than the longest used response frame (because of toggle and length byte). microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 16...
Page 17
Note: Standard parametrisation is required and is normally installed by the uti- lised DP configurators. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 17...
The bus termination has to be set at the beginning and at the end of the Profibus line (either internally or externally). microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 18...
3 through n, and the frame length is entered as byte 2 (= length byte). The length byte reflects the number of following bytes. The toggle byte is also increased by 1. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 20...
- DAP3 (standard), if the MRP ability of the interface shall be activated. ”Drag“ the needed “DAP“ to your Profinet system: microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 23...
Page 24
Large Displays Numeric LED with Ethernet TCP/IP / Profibus DP / Profinet / Serial Interface Consider a meaningful name for the device and rename the interface (here “miface1”) accordingly: microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 24...
Page 25
8 ms to avoid unnecessary network load)! After finishing the Profinet configuration, it must still be loaded into the Profinet controller: „Station/Save and Compile“ „PLC/Download...“ microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 25...
Tip: If you want to find the device of the marked line, you can click on „Flashing on“. LED 1 (green) of the corresponding interface starts to blink then. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 26...
*1: The interface ist mounted to the migan controller board. *2: The interface is connected with the migan controller board via RS485. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 27...
PN device must have the matching name. The communication between Profinet controller and the display (Profinet device) happens within cyclic data traffic. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 28...
Page 29
As soon as it changes, data of the received frame can be read out and next frame can be sent. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 29...
Bit 0 = Digital output 1 Output will be set, if corresponding bit = 1 * at communication with response frame microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 31...
Page 32
A point is set, if corresponding bit = 1 Depending on the display module (ordering option), only a decimal point or only a colon can be shown. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 32...
Status of a digital input = 1, if it’s set at the moment. Example Device address = 1, digital input 3 is set 01 02 04 55 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 34...
. / : * Depending on the display module (ordering option), only the decimal point or only the colon can be shown. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 35...
(MKS). Devices with Profibus or Profinet interface need two more bytes; see corresponding chapters “Operation”. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 36...
Page 37
Device address 23, display “1.23“, decimal point as ASCII character via the data bytes 3C 32 33 40 40 40 31 2E 32 33 3E microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 37...
Page 38
Example Device address = 1, set digital output 2, brightness = 80 % 3C 30 31 62 61 60 3E microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 38...
Page 39
Device address = 1, digital input 4 was set at least once since last query 3C 30 31 40 48 40 3E microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 39...
Do not attempt to repair the device yourself. The guarantee is rendered null and void if the device is tampered with by unauthorized persons. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 40...
“used” and that it has been purchased “as is”. No guarantee claims may be made in such cases. The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach ...
Change of address and title MPB 3.20 28.11.18 Change of titles, change page 33 and 34 Certified per DIN EN ISO 9001. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 43...
Need help?
Do you have a question about the Migan MPB FI/SI and is the answer not in the manual?
Questions and answers