microSYST migra MPB IZ User Manual

Large format led display with pulse counter

Advertisement

Quick Links

migan/migra MPB IZ
Large Format LED Display with Pulse Counter
User's Manual
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
 +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the migra MPB IZ and is the answer not in the manual?

Questions and answers

Summary of Contents for microSYST migra MPB IZ

  • Page 1 MPB IZ Large Format LED Display with Pulse Counter User’s Manual microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 2: Table Of Contents

    Device Configuration migan Device Configuration migra CONNECTOR PIN ASSIGNMENTS APPENDIX Declaration of Conformity Maintenance and Care Warranty / Liability Versions Overview microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 2...
  • Page 3: General

    (optional). Display options:  Counting value  Frequency  Number of revolutions  Cycle duration  Time microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 3...
  • Page 4: System Overview

    Counting input / counting direction Reset inputs for outputs (optional) BCD preselection inputs (optional) 2 relay outputs Voltage outputs (optional) (optional) microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 4...
  • Page 5: Technical Data

    IP54 or IP65 0 to +50 C (optional -20 to +50 °C) Operating temperature: -25 to +70 C Storage temperature: microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 5...
  • Page 6: Tips For The Start-Up

    Disconnect the power supply cable from the power supply. o Disconnect the power supply cable from the display. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 6...
  • Page 7: Description Of The Signals

    The input acts as reset input, if preset value = 0. The preset value can be set vial BCD preset values, MKS software, frame or script. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 7...
  • Page 8: Pulse Diagrams

    = 0 VDC Counting behaviour: *: The direction switching could possibly be executed a few milliseconds after changing the level. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 8...
  • Page 9: Incremental Input

    UP-counting happens. If channel B hurries ahead the channel A by 90 degrees, a DOWN-counting happens. This can be inverted with MKS software. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 9...
  • Page 10: Control Inputs

    = pulse duration The pulse duration t is adjustable from 0 to 255 ms. Pulse duration > 10 if value is 0. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 10...
  • Page 11: Device Configuration Migan

    -20...+50 °C (standard) ___________ °C -25...+50 °C (optional with heating) Housing dimension: _________x_________x_________mm Housing Material: Aluminum profile Stainless steel Sheet metal microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 11...
  • Page 12: Device Configuration Migra

    -20...+50 °C (standard) ___________ °C -25...+50 °C (optional with heating) Housing dimension: _______x_______x_______mm Housing Material: Aluminum profile Stainless steel Sheet metal microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 12...
  • Page 13: Connector Pin Assignments

    Optionally it’s possible to supply with the 7-Pole mains plug (230 VAC). Power Connector 24 VDC Assignment +24 VDC Power Connector 230 VAC (optional) Assignment (PE) microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 13...
  • Page 14 Depending on the display’s version, the voltage at this output can also be +24 VDC! Input Impedances Standard inputs: > 38 kΩ Incremental inputs: > 5 kΩ microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 14...
  • Page 15 Depending on the display’s version, the voltage at this output can also be +24 VDC! together with Pin 3, pulse inputs (previous page), max. current 0,5 A microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 15...
  • Page 16 The ouput voltage of Pin 2 can be used for wiring the preselection inputs. If the wiring shall happen with an external voltage, its GND must be connected to Pin 1. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 16...
  • Page 17  2 ms LE 10 LE 10 LE 10 LE 10 LE 10 LE 10  Set preset input (HIGH-active). microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 17...
  • Page 18: Appendix

    2014/35/EU Richtlinie +A2:2013 Low Voltage Directive RoHS Richtlinie 2011/65/EU EN50581:2012 RoHS Directive Windischeschenbach, 16.11.2017 Manuel Raß Geschäftsführer / General Manager microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 18...
  • Page 19: Maintenance And Care

     Observe all notes and instructions included in this user’s manual. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 19...
  • Page 20: Warranty / Liability

    “as is”. No guarantee claims may be made in such cases. The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 20...
  • Page 21: Versions Overview

     migan MPB; migra  migra MPB 3.00 16.11.16 3.10 13.11.17 Change of address and title MPB Certified per DIN EN ISO 9001. microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de Page 21...