microSYST migra AD User Manual

Graphics compatible large format led display with a-d converter

Advertisement

Quick Links

migra AD
Graphics Compatible Large Format LED Display with A-D Converter
User's Manual
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
 +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the migra AD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for microSYST migra AD

  • Page 1 AD Graphics Compatible Large Format LED Display with A-D Converter User's Manual microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 2: Table Of Contents

    Settings with “micon AD” 3.3.1 Settings with “micon” 3.3.2 CONNECTOR PIN ASSIGNMENTS APPENDIX Maintenance and Care Warranty / Liability Versions Overview Page 2 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 3: General

    Thus integration into existing equipment or systems is easy and simple. 2 Overview PC (RS232) Parameter setting 4 A-D Inputs migra AD Specific functions Page 3 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 4: Technical Data

    Operating temperature: 0 to +50 C (optionally –20 to +50 °C) -25 to +70 C Storage temperature: Features: under and overflow display, relay output (optional) Page 4 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 5: Device Details

    24 V DC Protection: IP54 IP65 Housing dimensions: _________x_________x_________mm Housing colour: RAL _____________ Housing material: Aluminium profile Stainless steel Sheet material Page 5 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 6: Notes For The Start-Up

    Disconnect the power supply cable from the power supply. o Disconnect the power supply cable from the display. Page 6 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 7: Device Configuration

     Averaging  Blinking rate  Bargraph  Status outputs Please refer to the user’s manual “micon AD” for further information’s. Page 7 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 8: Settings With "Micon

    V2 -> measuring channel 3 V3 -> measuring channel 4 Please see user’s manual “micon” for additional information concerning the display configuration. Page 8 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 9 Depending on the character set, the option “monospaced” must be set. For more information concerning variables see user’s manual “micon”. Page 9 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 10 The command for querying variable 2 must be added to the macro list in or- der to display the value immediately after the startup. Please see user’s manual “micon” for further description. Page 10 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 11: Connector Pin Assignments

    If using only one current input, channel 3 is used! 9-Pole Sub-D Plug Connectors (RS232-AD / RS232-migra) Assignment RS232 RxD RS232 TXD RS232 GND Page 11 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 12 250 mADC or 250 mAAC peak 7-Pole Mains Plug (230 VAC) Assignment (PE) 3-Pole Circular Connector (24 VDC, optional mounted) Assignment +24 VDC Page 12 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 13: Appendix

    Richtlinie 2014/35/EU +A2:2013 Low Voltage Directive RoHS Richtlinie 2011/65/EU EN50581:2012 RoHS Directive Windischeschenbach, 16.11.2017 Manuel Raß Geschäftsführer / General Manager Page 13 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 14: Maintenance And Care

    Do not attempt to repair the device yourself. The guarantee is rendered null and void if unauthorized persons tamper with the device. Page 14 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 15: Warranty / Liability

    No guarantee claims may be made in such cases. The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well. Page 15 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...
  • Page 16: Versions Overview

    1.60 3/19/15 SC/MC removed 1.70 4/29/16 Declaration of conformity 1.80 11/16/17 Change of address Certified per DIN EN ISO 9001. Page 16 microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach  +49 9681 91960-0,  +49 9681 91960-10, info@microsyst.de, www.microsyst.de...

Table of Contents