Identifying The Airflow Direction; Air_Flow And Encr Error Monitoring; Power Supply And Fan Assembly Unit Fault Indicators; Power Supply And Fan Assembly Task Guide - IBM SAN64B-6 Installation, Service And User Manual

Storage networking
Hide thumbs Also See for SAN64B-6:
Table of Contents

Advertisement

Identifying the airflow direction

The power supply and fan assemblies are identified by the following airflow directions:
• Intake power supply and fan assembly with an orange "I" label or without any label: Pulls air from
the nonport-side of the switch and exhausts it out the port side.
• Exhaust power supply and fan assembly with a green "E" label: Pulls air from the port side of the
switch and exhausts it out the nonport-side.

AIR_FLOW and ENCR Error Monitoring

Starting with FOS 9.0.0, MAPS added support for the following monitoring systems:
• FAN_AIRFLOW_MISMATCH
• ENCR_BLK
• ENCR_DISC
• ENCR_SHRT_FRM

Power supply and fan assembly unit fault indicators

Use one of the following methods to determine the status of the power supply and fan assemblies:
• Check the power supply and fan assembly status LED. See "Interpreting nonport-side LEDs" on page
57.
• In Web Tools, click the Power Status icon.
• Enter the psShow command at the prompt to display power supply and fan assembly status, as shown
in the following example:
Device:admin> psshow
Power Supply #1 is OK
Power Supply #2 is OK

Power supply and fan assembly task guide

You can perform an easy set of steps to install or replace a power supply and fan assembly or to replace
both power supply and fan assemblies. By default, both of the power supply and fan assemblies are
installed in the device.
Installing an additional power supply and fan assembly (hot-install)
If your device is up and running with a single power supply and fan assembly and you want to install an
additional power supply, complete the following steps.
– Nonport-side air intake
– Port-side air exhaust
– Back-to-front (nonport-side to port-side)
airflow
– Part numbers ending with -R
– Nonport-side air exhaust
– Port-side air intake
– Front-to-back (port-side to nonport-side)
airflow
– Part numbers ending with -F
Chapter 7. Power supply and fan assembly 63

Advertisement

Table of Contents
loading

Table of Contents