Table 9. System status LED patterns during normal operation (continued)
LED color
Steady amber (for more than a
few minutes)
Flashing amber/green

System status LED

Refer to the following table to interpret the management port LEDs.
Table 10. Management Port LED patterns during normal operation
LED Function/State
Link/Speed—Green LED is on
Link/Speed—LED is off
Activity—Green LED is blinking

FC port status LED

Refer to the following table to interpret the FC port status LEDs.
Table 11. SFP+ FC port status LED patterns during normal operation
LED color
No light
Steady green
Status of hardware
Unknown state, boot failed, or
the system is faulty.
Note: Once POST completes and
the switch has failed, steady
amber may result.
Attention is required. A number
of variables can cause this status,
including a single power supply
failure, a fan failure, or one or
more environmental ranges have
been exceeded.
Status of Hardware
1000Mb/s link
10/100Mb/s link
Presence of activity
Status of hardware
Indicates one of the following:
• No signal or light carrier (media
or cable) detected.
• Device may be currently
initializing.
• Connected device is configured
in an offline state.
Port is online (connected to
external device) but has no
traffic.
Recommended action
Perform the following steps:
1. Connect a serial cable to the
system.
2. Reboot the system.
3. Check the failure indicated on
the system console
4. Contact your solution
provider.
Check the management interface
and the error log for details on
the cause of the status.
Contact your solution provider.
Recommended action
• Verify the power LED is on, and
check the SFP+ and cable.
• Verify the device is not
currently being initialized.
• Verify the status of the
connected device.
No action required.