7.3.4 Calculating CO2 with air correction
The standard formula has been adjusted for air correction:
CO
%
by weight
2
where : A
The CO2 value read should be corrected as follows:
actual
CO
%
by
weight
2
Page 26 of 49
A
p
bar
p
= conversion factor/compensation factor,
p
= gas equilibrium pressure,
patm
= atmospheric pressure in bar,
Vair
= air volume in ml read on the IAM,
Vheadspace = headspace volume of the bottle or can in ml as
determined by weighing or with a template,
C
= product-dependent factor
D
= product-dependent factor (
T
= liquid temperature measured in C.