Table 28: Environmental Data
Environmental standards
Temperature range
Other operating conditions
Storage & transportation
conditions (packaged)

1600 W Power Supplies Technical Specifications

Three 1600 W power supply units are available for use with SLX 9740 switch routers:
1600W AC power supply - front-to-back airflow (part no. XN-ACPWR-1600W-F)
1600W AC power supply - back-to-front airflow (part no. XN-ACPWR-1600W-R)
1600W DC power supply - front-to-back airflow (part no. XN-DCPWR-1600W-F)
86
ExtremeRouting SLX 9740 Hardware Installation Guide
ExtremeRouting SLX 9740 Technical Specifications
EN/ETSI 300 019-2-1 v2.1.2 (2000 - 2009) - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 (1999 - 09) - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 (2003 - 04) - Class 3.1e Operational
EN/ETSI 300 753 (1997-10) - Acoustic Noise
ASTM D3580 Random Vibration Unpackaged 1.5G
• Front-to-back airflow: 0°C to 40°C (32°F to 104°F) up to 1800m
(6,000 ft)
• Back-to-front airflow: 0°C to 25°C (32°F to 77°F) up to 457m (1500
ft)
Humidity: 5% to 90% relative humidity, non-condensing
Altitude: 0 to 4,500 meters (14,763 feet)
Storage temperature: -25°C to 55°C (-13°F to 131°F)
Operational shock (half sine): 30 m/s 2 (3 G), 11 ms, 60 shocks
Operational random vibration: 3 to 500 Hz at 1.5 G rms
Transportation temperature: -40°C to 70°C (-40°F to 158°F)
Humidity: 5% to 95% relative humidity, non-condensing
Packaged shock (half sine): 180 m/s 2 (18 G), 6 ms, 600 shocks
Packaged sine vibration: 5 to 62 Hz at velocity 5 mm/s,
62 to 500 Hz at 0.2 G
Packaged random vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct.
from 20 to 200 Hz
14 drops minimum on sides and corners at 42 in (<15 kg box)