1.Loosen the screws and remove E parts cover from the unit.
2.Connect the cables respectively to the corresponding terminals
of the terminal board of the outdoor unit (see the wiring diagram),
and if there are signals connected to the plug, just conduct butt joint.
3.Ground wire: Remove the grounding screw out of the electric
bracket, cover the grounding wire end onto the grounding screw
and screw it into the grounding hole.
4.Fix the cable reliably with fasteners (Pressing board).
-
5.Put the E parts cover back in its original place and fasten
it with screws.
Constant speed
L
N
To power
L
N
To power
NOTE:
※ This manual usually includes the wiring mode for the different kind of A/C.
We cannot exclude the possibility that some special type of wiring diagrams
are not included .
The diagram are for reference only. If the entity is difference with this wiring
diagram, please refer to the detailed wiring diagram adhered on the unit which
you purchased.
Outdoor unit installation
Wiring Connection
-
Wiring diagram
1
N(2)
3
To Indoor unit
1
N(2)
3
4
5
To Indoor unit
Connector
If there is a connector,
connect it directly.
- 20 -
Variable speed
N
S
L
To Indoor unit
S
N
Lo
L
To Indoor unit
-
E parts cover
1
2
N
L
To power
To power

Hide quick links:

Advertisement

Table of Contents