DESCRIPTION

The 12 SEER Series condensing unit is the outdoor
part of a versatile system of air conditioning. It is
designed to be custom-matched with one of UPG's
complete line of evaporator sections, each designed to
serve a specific function. Matching Air Handlers are
available for upflow, downflow or horizontal applica-
tions to provide a complete system. Electric Heaters
are available if required. Add-On coils are available for
use with upflow, downflow or horizontal furnaces and
air handlers.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
• COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted textured champagne
finish insure less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Available in sweat connect models only.
The unit contains enough refrigerant for matching indoor
coils and 15 feet of interconnecting piping. The small base
dimension means less space is required on the ground or
roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls
and the molex plug in the control box connecting the con-
denser fan, make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
036-21106-005 Rev. B (0505)

Advertisement

Table of Contents
loading

Summary of Contents for York AC018X1222

  • Page 1 Visit us on the web at www.york.com for the most • U.L. and C.U.L. listed - approved for outdoor application. up-to-date technical information.
  • Page 2 036-21106-005 Rev. B (0505) Physical and Electrical Data MODEL AC018X1222 AC024X1222 AC030X1222 AC036X1222 AC042X1221 AC048X1222 AC060X1224 Unit Supply Voltage 208/230 – 1 – 60 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 10.1 14.1 16.5 19.7 26.2 28.5 37.5 Max.
  • Page 3 036-21106-005 Rev. B (0505) Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit AC018X1222 AC024X1222 AC030X1222 AC036X1222 AC042X1221 AC048X1222 AC060X1224 – Unit Orifice (s) Factory R-22 Charge, lbs-oz. 4 - 9 4 - 7...
  • Page 4 036-21106-005 Rev. B (0505) Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued) Outdoor Unit AC018X1222 AC024X1222 AC030X1222 AC036X1222 AC042X1221 AC048X1222 AC060X1224 – Unit Orifice (s) Factory R-22 Charge, lbs-oz. 4 - 9 4 - 7...
  • Page 5: Unitary Products Group

    UNIT MODEL SEER RATED TOTAL SENSIBLE ELECTRIC MODEL MODEL CAPACITY CAPACITY W/O TXV HEAT KW WITH TXV 1 PH 12 SEER AC WITH N-AH / G2FD AC018X1222 N1AHB0806 2,5,8,10 G2FD024(S,H)17 19.6 13.2 12.50 12.50 11.60 N1AHB0806 2,5,8,10 G2FD024(S,H)17 23.6 16.9 12.00...
  • Page 6 11.50 – G1HA024H14T 19.2 13.6 12.00* 11.60 – G1HD024 20.0 13.5 12.50* 12.50 11.70 G1NA030S17K 20.0 13.5 12.75* 12.75 11.75 AC018X1222 G1NA030S21M 20.0 13.5 12.50* 12.50 11.75 14,17 G1UA024S14,17 19.2 13.0 12.00* 12.00 11.35 14,17 G2FD024(S,H)14,17 19.6 13.2 12.50* 12.50 11.60...
  • Page 7 036-21106-005 Rev. B (0505) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL UNIT MODEL CFM RANGE RATED NET MBH SEER MODEL SEER + TXV (MIN.-MAX.) TOTAL SENS. W/O TXV G1FA036S14 1200 33.6 23.4 11.50* 11.50 10.60 17,21...
  • Page 8 35.94 3.12 31.92 3.76 27.86 4.54 68.5 18.77 1.45 15.80 1.63 13.53 1.77 68.5 39.29 3.15 35.11 3.77 30.80 4.55 AC018X1222 AC042X1221 76.0 20.48 1.47 17.70 1.66 15.04 1.83 76.0 42.48 3.21 38.17 3.84 33.70 4.63 84.0 21.99 1.48 19.60 1.70...
  • Page 9 036-21106-005 Rev. B (0505) TYPICAL INSTALLATION MINIMUM 18” SERVICE ACCESS THERMOSTAT TO FURNACE OR CLEARANCE ON ONE SIDE 60” OVERHEAD AIR HANDLER CLEARANCE WEATHERPROOF TERMINAL BLOCK DISCONNECT SWITCH NEC CLASS 1 WIRING NEC CLASS 2 WIRING 10” CLEARANCE TO INDOOR COIL COIL AREA SEAL OPENING(S) WITH NOTE: ALL OUTDOOR WIRING...
  • Page 10 036-21106-005 Rev. B (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AC018X1222 INDOOR COIL MODEL NO. G1FA024S14,17 IDCFM CONDENSING| ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 20.1 19.3 18.2 20.1 19.4 18.6 20.1 19.5 18.9 S.C. 11.7 11.5...
  • Page 11 036-21106-005 Rev. B (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AC24X1222 INDOOR COIL MODEL NO. G1FA036S17,21 IDCFM 1000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 25.4 24.2 22.5 25.6 24.5 23.2 25.8 24.9 23.9 S.C. 14.6 14.6 13.8...
  • Page 12 036-21106-005 Rev. B (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AC030X1222 INDOOR COIL MODEL NO. G1FA036S17,21 IDCFM 1000 1200 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 31.9 30.6 28.9 27.4 30.9 29.4 23.0 31.2 29.9 S.C.
  • Page 13 036-21106-005 Rev. B (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AC036X1222 INDOOR COIL MODEL NO. G1FA048S21 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 36.7 34.3 32.3 36.9 34.9 32.8 37.2 35.4 33.2 S.C.
  • Page 14 036-21106-005 Rev. B (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AC042X1221 INDOOR COIL MODEL NO. G1FA048S21 IDCFM 1200 1400 1600 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 46.4 45.7 43.0 46.4 45.9 43.3 46.5 46.0 43.5 S.C.
  • Page 15 036-21106-005 Rev. B (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AC048X1222 INDOOR COIL MODEL NO. G1FA048S21 IDCFM 1375 1575 1775 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 52.8 49.9 45.4 53.5 50.6 46.8 54.2 51.3 48.2 S.C.
  • Page 16 036-21106-005 Rev. B (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AC060X1224 INDOOR COIL MODEL NO. G1FA060S21,24 IDCFM 1600 1800 2000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 53.8 59.2 63.5 68.4 54.8 60.2 64.5 69.5 55.2 60.7 64.9...
  • Page 17 036-21106-005 Rev. B (0505) MATCHING INDOOR COMPONENTS ADD-ON COILS - FOR FURNACE APPLICATIONS G1NA G1UA UNCASED G1HD 1/2 CASED UPFLOW HORIZONTAL DUCT UPFLOW G2FD* MULTI-POSITION G1FA (UPFLOW, HORIZONTAL FULL CASED AND DOWNFLOW) UPFLOW * Available with factor installed horizontal drain pan. AIR HANDLERS - FOR NON-FURNACE APPLICATIONS N1AH OR N1VS MODULAR BLOWER...
  • Page 18 036-21106-005 Rev. B (0505) NOTES Unitary Products Group...
  • Page 19 036-21106-005 Rev. B (0505) NOTES Unitary Products Group...
  • Page 20 NOTES Subject to change without notice. Printed in U.S.A. 036-21106-005 Rev. B (0505) Copyright © by York International Corp. 2005. All rights reserved. Supersedes: 036-21106-005 Rev. A (0904) Unitary 5005 Norman Products York Group Drive 73069...

Table of Contents