Power Supply Units; Cpu Modules; Specifications - Mitsubishi Electric MELSEC iQ-R Series Manual

Programmable logic controllers
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Power Supply Units

Parts and controls
A
B
H
C
6
D
E
G
No.
Description
Power LED
Indicates the operating status of the power supply module.
A
P On: Normal operation
P Off: Power-off, power failure, or hardware failure
Error signal output
Turns on when the entire system operates normally. (M4 screw)
This contact turns off (opens) when the power is not supplied, a stop
error (including reset) occurs in the CPU module, or the fuse is
blown.
B
In a multiple CPU system, the contact turns off when a stop error
occurs in any of the CPU modules.
The contact is off at all times when the module is mounted on an
extension base unit.
FG frame ground terminal
a
A functional ground terminal connected to the shield pattern of the
C
printed circuit board. (M4 screw)
LG line ground terminal
a
A functional ground terminal for the power supply input filter. For
D
AC input, the terminal has one-half the potential of the input volt-
age. (M4 screw)
Power input terminal
A power input terminal for the power supply module. The input power
E
supply differs depending on a power supply module. (M4 screw)
Terminal cover
F
A protective cover for the terminal block.
Production information marking
G
Shows the production information (16 digits) of the module.
+24 V and 24 G terminals
b
H
Used for a device that requires a supply of 24 V DC (M3.5 screw).
The power is supplied to a device through the external wiring.
a
Individually ground the FG and LG terminals with a ground resistance of 100  or less.
b
The R62P only provides these terminals.

Specifications

Power
Power input
Power
Supply
consump-
AC (+10%, –15%) DC (+30%, –35%)
Unit
tion
R61P
100–240 V
130 VA
100–240 V
120 VA
R62P
a
R63P
24 V
50 W
R64P
100–240 V
160 VA
a
In addition to the 5 V DC output the R62P power supply also has an additional
output with 24 V DC/0.6 A.
The 5 V DC output from the power supply units is fed directly into the base
unit. It cannot be tapped from any of the terminals.

CPU Modules

Parts and controls
R00CPU
A
H
B
I
C
D
E
F
G
No.
Description
Indicates the operating status of the CPU
module and the error level.
READY
READY LED-ERROR LED status:
P ON-OFF: Normal operation
P ON-ON: Minor error
P ON-BLINK: Moderate error
P BLINK-ON: Minor error
ERROR
P BLINK (every 2 s)-OFF: Initial processing
P OFF-ON/BLINK: Major error
Indicates the operating status of the
LED
A
program.
P ON: Being executed (RUN state)
P RUN
P BLINK: Being suspended (PAUSE state).
P OFF: Stopped (STOP state) or stop error.
Indicates the status of the annunciator (F).
P ON: Annunciator (F) on
USER
P OFF: Normal operation
Indicates the status of the function being
FUNC
executed.
Upper front cover
B
For protection of the switch, battery com-
partment, and USB port.
Lower front cover
C
Indicates the communication speed and
link status of Ethernet.
SPEED
4
P ON: Link up (100 Mbps)
P OFF: Link-down or link-up (10 Mbps)
LED
Indicates the data communication status
over Ethernet.
Output
SD/RD
5
P ON: Data being sent or received
current
P OFF: Data not being sent nor received
6.5 A
Production information marking
6
Shows the production information (16 digits) of the module.
3.5 A
Ethernet port (RJ45) (on bottom side)
G
6.5 A
Battery compartment for battery FX3U-32BL
H
9 A
Operating mode switch
P RUN: Execute PLC program
I
P STOP: Stop executing PLC program
P RESET: Resets error messages, initialises CPU etc.
Battery connector
J
USB port for connection of a programming unit
K
R01CPU, R02CPU
with open front covers
B
J
K
C
D
E
F
G
No.
Description
READY
ERROR
P RUN
LED
A
C RDY
USER
C ACS
FUNC
Upper front cover
B
Lower front cover
C
SPEED
4
LED
SD/RD
5
Production information marking
6
Shows the production information (16 digits) of the module.
Ethernet port (RJ45) (on bottom side)
G
Battery compartment for battery FX3U-32BL
H
No.
Description
with open front covers
Operating mode switch
P RUN: Execute PLC program
I
P STOP: Stop executing PLC program
P RESET: Resets error messages, initialises CPU etc.
Battery connector
J
USB port for connection of a programming unit
A
K
J
SD memory card disable switch
L
H
SD memory card slot
M
K
I
L
M
Indicates the operating status of the CPU
module and the error level.
READY LED-ERROR LED status:
P ON-OFF: Normal operation
P ON-ON: Minor error
P ON-BLINK: Moderate error
P BLINK-ON: Minor error
P BLINK (every 2 s)-OFF: Initial processing
P OFF-ON/BLINK: Major error
Indicates the operating status of the
program.
P ON: Being executed (RUN state)
P BLINK: Being suspended (PAUSE state).
P OFF: Stopped (STOP state) or stop error.
Indicates the availability of the SD memory
card.
P ON: Available
P BLINK: Ready
P OFF: Not available or not inserted
Indicates the status of the annunciator (F).
P ON: Annunciator (F) on
P OFF: Normal operation
Indicates the access status of the SD
memory card.
P ON: Being accessed
P OFF: Not accessed
Indicates the status of the function being
executed.
For protection of the switches, battery
compartment, memory card slot, and USB
port.
Indicates the communication speed and
link status of Ethernet.
P ON: Link up (100 Mbps)
P OFF: Link-down or link-up (10 Mbps)
Indicates the data communication status
over Ethernet.
P ON: Data being sent or received
P OFF: Data not being sent nor received

Advertisement

Table of Contents
loading

Table of Contents