SFU-0302 SSE
Error Description
With activated speed
sensor:
The spindle runs properly,
but sometimes there
appears the message
Encoder Error.
Error Without Spindle,
Cable is displayed
BMR GmbH
M a n u a l
Cause
Loose connection in spindle, spindle
cable or at the connectors
Disturbances on the signal or the
signal amplitude is too low
> sensor wires in spindle cable are
not shielded
Spindle cable is defective
Spindle cable too long
With activated spindle test, a test
current is send via spindle cable to the
spindle by applying a voltage at output
lines. In case that this current is too
low, or a wrong spindle characteristic
selected, it does not match to the
reference values and the spindle test
fails.
2014-03-17
Fixing
> Check spindle cable and exchange
potentially
> Check connectors
> Exchange spindle cable
> for verification test exchange spindle
> Check the 3 spindle phase wires
> Check, if the proper characteristic is
selected.
> Increase value for start voltage in the
spindle characteristic
-> contact BMR
> Deactivate function "Spindle test"
– 26–