Spindle Connection At Screw Terminals - BMR SFU-0302-SSE Manual

Frequency converter
Table of Contents

Advertisement

SFU-0302 SSE

6.3 Spindle connection at screw terminals

-
-
1
2
PE PE
U
V
6.4 Mains
L1 N PE
!
Control cables, supply cables and motor cables must be isolated
from each other. Shielded cables are to be preferred !
6.3 RS232
(D-Sub 9pin male)
Pin
Description
2
RxD
3
TxD
5
GND
use a standard zero-modem-cable for connection to PC
BMR GmbH
M a n u a l
3
4
5
6
FP SGND
W
PTC
Function
receive-data (data to converter)
send-data (data from converter)
Ground
2014-03-17
PE
Earth Protection GND
PE
Earth Protection GND
U
Spindle Phase 1
V
Spindle Phase 2
W
Spindle Phase 3
SGND Signal-GND for FP- and PTC-Signals
FP
Hall-Sensor-Signal (Spindle speed)
PTC
PTC-Signal (Spindle Temperature)
L1
Mains L1
N
Neutral N
PE
Earth Protection GND
– 12–
E

Hide quick links:

Advertisement

Table of Contents
loading