Rice Lake BenchPro BP-P Operation Manual

Rice Lake BenchPro BP-P Operation Manual

Postal bench scale

Advertisement

Quick Links

BenchPro
BP-P Postal Bench Scale
Operation Manual
July 22, 2020
PN 180557 Rev E

Advertisement

Table of Contents
loading

Summary of Contents for Rice Lake BenchPro BP-P

  • Page 1 BenchPro ™ BP-P Postal Bench Scale Operation Manual July 22, 2020 PN 180557 Rev E...
  • Page 2 All information contained within this publication is, to the best of our knowledge, complete and accurate at the time of publication. Rice Lake Weighing Systems reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.
  • Page 3: Table Of Contents

    Second Operator Display Option (PN 174784) ........... . . 26 Technical training seminars are available through Rice Lake Weighing Systems.
  • Page 4 BenchPro Postal BP-P Scale Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost. Visit www.ricelake.com/webinars www.RiceLake.com Visit our website...
  • Page 5: Introduction

    Do not operate or work on this equipment unless this manual has been read and all instructions are understood. Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice Lake Weighing Systems dealer for replacement manuals.
  • Page 6: Setup

    This section provides information regarding the setup of the BenchPro Postal scale. Unpacking the Scale Remove all contents from the packaging. Inspect contents for damage. Contact Rice Lake Weighing Systems and the shipper immediately if items are damaged. Each carton contains the following: •...
  • Page 7: Power

    The USB connection can be used as an HID device or USB power supply. The scale is equipped with a standard bi-directional RS-232 port for connection to a PC. Adapter RS-232 Display Figure 2-3. Junction Box Connections – Back Of Unit © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 8: Operation

    BenchPro Postal BP-P Scale Operation This section provides information regarding the operation of the BenchPro Postal scale. Keys and Symbols For reference only: Capacity marking changes based on capacity of the scale Postal Scale: 0-7 lb x 0.05 oz / 7-70 lb x 0.2 oz Figure 3-1.
  • Page 9: Initial Power Up

    The weight value is zero and G/B displays, indicating the scale has returned to the Gross/Brutto mode. Enabling tare could violate metrological approvals. Note © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 10: Configuration

    BenchPro Postal BP-P Scale Configuration This section provides information regarding the configuration of the BenchPro Postal scale. User Menu The user menu provides the configuration settings for non Legal for Trade parameters. To enter the user settings menu: 1. Press at the same time 2.
  • Page 11: Service Menu

    8. Set the PCB compartment door back in place and reinstall the hex screw to secure it. 9. Place the weigh platter back onto the scale. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 12: Configure Service Parameters

    BenchPro Postal BP-P Scale 4.2.2 Configure Service Parameters To navigate the service setting menu: • Press to scroll through the parameters and settings • Press to select a parameter • Press to return to the previous parameter • Once all parameters have been set, navigate to the done parameter and press to confirm and save settings Appears if is set to...
  • Page 13 • div-A – Display internal counts after auto zero tracking • div-O – Display internal counts Done – exit the configuration menu, save settings and return to weigh mode  Table 4-2. Service Menu Parameter Settings (Continued) © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 14: Gravity Mode Setting

    The BenchPro is a Legal for Trade device. Rice Lake Weighing Systems recommends contacting an authorized scale technician to perform a calibration using certified test weights.
  • Page 15: Calibration

    This is the internal counts of the load cell at zero weight. 13. Press to accept and perform a zero calibration.  displays. 14. Press once.  displays. 15. Press to accept. XXX lb or XXX kg displays. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 16: Linear Calibration

    Linear Calibration Only perform a linear calibration function if instructed by Rice lake Weighing Systems and an authorized scale IMPORTANT technician. The BenchPro includes an optional linear calibration feature. This is an additional feature to perform after a span calibration has been completed at maximum capacity and linear calibration is performed with two lower calibration weight values.
  • Page 17 If  displays, there is a calibration error. Ensure the correct calibration weight value was selected in comparison to the actual calibration weight used. See Section 7.1 on page 22 for more information on troubleshooting. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 18: Communication

    Software Compatibility Chart, see Section 6.3 on page 15. The most current version of the compatibility chart can be found on the Rice Lake Weighing Systems website. Scale Com Port DB-9 (9-pin) female connector Powered USB 2.0 COM port (USB HID compatible software only) DB-9 (9-pin) female connector RS-232/USB converter Table 6-1.
  • Page 19: Usb

    USB Specs • Vendor ID = 1C19 • Product ID = 0002 Model Interface Protocols • SMA, Auto-1, Auto-2, Print, NCI, USB Hid (USB port only) © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 20: Interface Protocols

    BenchPro Postal BP-P Scale Interface Protocols 6.4.1 NCI General Serial Communications Protocol Command W<CR> (57h,0dh) Over capacity <LF> <U> <U> <CR> <LF> <H1> <H2> <CR> <ETX (invalid data) > Under capacity <LF> – – – – – – – – <U>...
  • Page 21 1=RAM error 1=Flash ROM error 0=eeprom ok 0=calibration ok 1=eeprom error 1=calibration error Always 1 Always 1 Always 1 Always 1 Always 0 Always 0 Parity Parity Table 6-14. Bit Definition <H1-H3> © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 22: Sma Interface Protocol

    BenchPro Postal BP-P Scale 6.4.2 SMA Interface Protocol Command <LF>W<CR> (0Ah,57h,0dh) In lb/oz/kg/g <LF> <s> <r> <n> <m <f> <W> <W> <W> <W> <W> <W> <W> <W> <W> <U> <U> <U> <CR (Normal Data) > > In lb/oz/kg/g <LF> <s> <r> <n> <m <f>...
  • Page 23 <LF>T<CR> (0Ah,54h,0dh) Simulate TARE Key <LF> <s> <r> <n> <m> <f> <W> <W> <W> <W> <W> <W> <W> <W> <W> <U> <U> <U> <CR > Table 6-20. Request Scale to Tare © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 24 BenchPro Postal BP-P Scale Command <LF>M<CR> (0Ah,4Dh,0dh) Response <LF> <s> <r> <n> <m <f> <W <W <W <W <W <W <W <W <W <U> <U> <U> <CR> > > > > > > > > > > Table 6-21. Return Tare Weight Command <LF>C<CR>...
  • Page 25: Sealing Scale For Weights And Measures

    2. Guide sealing wire through the drilled hex screw and through the PCB compartment door handle. 3. Seal the wire to secure. Sealing Wire Figure 6-4. Top View with Weigh Platter Removed © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 26: Maintenance And Troubleshooting

    BenchPro Postal BP-P Scale Maintenance and Troubleshooting Prior to calling customer support, have the software type and software version number available. These are displayed briefly when powering on the scale. Troubleshooting Error Code Description Possible Cause Corrective Action Calibration error Ensure the calibration value selected is equal to Repeat calibration;...
  • Page 27: Compliance

    2014/30/EU EMC EN 55024:2010+A1:2015, EN 55032:2015, EN 44032:2012+AC:2013, CISPR 32:2012, EN 61000-3-2:2014, EN 61000-3-3:2013 2014/35/EU LVD EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 2011/65/EU RoHS EN 50581:2012 __________________________ ____________________ ____ __________________________ __________________________ June 8, 2018 __________________________ __________________________ © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 28: Specifications

    BenchPro Postal BP-P Scale Specifications Dynamic Response Response time for stable weight: 0–1,000 d, 1,000 ms, maximum mean average 1,000 d +, 1,500 ms, maximum mean average Internal Resolution 500,000 internal count minimum Overload Protection Corner and center overload protection Power In-line Power Supply (included) Input...
  • Page 29: Dimensions

    Table 9-2. BenchPro Options 9.2.1 Column Bracket and Post Option (PN 174783) An optional column bracket is available for use with the remote display (not included). Figure 9-2. Optional Column Bracket and Post © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 30: Tabletop Display Post Option (Pn 183103)

    BenchPro Postal BP-P Scale 9.2.2 Tabletop Display Post Option (PN 183103) An optional 16'' high desktop display mount post is available for use with the remote display (not included). The mounting post has provisions to secure it to a table or counter using the mounting holes and adequate hardware. The remote display attaches to the mounting bracket using two magnets which are included with each display.
  • Page 32 Specifications subject to change without notice. Rice Lake Weighing Systems is an ISO 9001 registered company. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319...