Rice Lake BenchPro Series Operation Manual

Rice Lake BenchPro Series Operation Manual

Bp-r retail bench scales
Hide thumbs Also See for BenchPro Series:

Advertisement

BenchPro
BP-R Retail Bench Scales
Operation Manual
July 22, 2019
PN 187561 Rev D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BenchPro Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Rice Lake BenchPro Series

  • Page 1 BenchPro ™ BP-R Retail Bench Scales Operation Manual July 22, 2019 PN 187561 Rev D...
  • Page 2 All information contained within this publication is, to the best of our knowledge, complete and accurate at the time of publication. Rice Lake Weighing Systems reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.
  • Page 3: Table Of Contents

    Load Cell Wiring ..................23 Technical training seminars are available through Rice Lake Weighing Systems.
  • Page 4 Second Operator Display Option (PN 174784) ........... . . 26 Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost.
  • Page 5: Introduction

    Do not operate or work on this equipment unless this manual has been read and all instructions are understood. Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice Lake Weighing Systems dealer for replacement manuals.
  • Page 6: Setup

    • USB cable • RS-232 cable • Stainless steel/mild steel weigh platter Inspect contents for damage. Contact Rice Lake Weighing Systems and the shipper immediately if items are damaged. Scale Setup 1. Remove the protective cover from the weigh platter.
  • Page 7: Power

    The USB connection can be used as an HID device or USB power supply. The scale is equipped with a standard bi-directional RS-232 port for connection to a PC. Adapter RS-232 Display Figure 2-3. Junction Box Connections – Back Of Unit © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 8: Operation

    BenchPro – Retail Bench Scales Operation This section provides information regarding the operation of the Rice Lake Weighing Systems BenchPro Retail scale. Keys and Symbols For reference only: Capacity marking changes based on capacity of the scale 30 lb x 0.01 lb / 480 oz x 0.2 oz / 15 kg x 0.005 kg Figure 3-1.
  • Page 9: Initial Power Up

    3. Remove the item or container from the scale platform and press to return the scale to the gross mode. The weight value is zero and G/B displays, indicating the scale has returned to the Gross/Brutto mode. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 10: Configuration

    BenchPro – Retail Bench Scales Configuration This section provides information regarding the configuration of the Rice Lake Weighing Systems BenchPro Retail scales. User Menu The user menu provides the configuration settings for non Legal for Trade parameters. To enter the user settings menu: •...
  • Page 11: Service Menu

    8. Set the PCB compartment door back in place and reinstall the hex screw to secure it. 9. Place the weight platter back onto the scale. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 12: Configure Service Parameters

    BenchPro – Retail Bench Scales 4.2.3 Configure Service Parameters To navigate the service setting menu: • Press to scroll through the parameters and settings • Press to select a parameter • Press to return to the previous parameter • Once all parameters have been set, navigate to the done parameter and press to confirm and save settings Figure 4-3.
  • Page 13 • div-O – Display internal counts Done – exit the configuration menu, save settings and return to weigh mode  Bold indicates factory default setting Table 4-2. Service Menu Parameter Settings (Continued) © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 14: Gravity Mode Setting

    The BenchPro is a Legal for Trade device. Rice Lake Weighing Systems recommends contacting an authorized scale technician to perform a calibration using certified test weights.
  • Page 15: Calibration

    Calibration Calibration This section provides information regarding the calibration of the Rice Lake Weighing Systems BenchPro Retail scale. Span Calibration The BenchPro allows for calibration with weight values other than max capacity. Table 5-1 displays the alternate calibration weights for each model.
  • Page 16: Linear Calibration

    Linear Calibration Only perform a linear calibration function if instructed by Rice lake Weighing Systems and an authorized scale IMPORTANT technician. The BenchPro includes an optional linear calibration feature. This is an additional feature to perform after a span calibration has been completed at maximum capacity and linear calibration is performed with two lower calibration weight values.
  • Page 17 If  displays, there is a calibration error. Ensure the correct calibration weight value was selected in comparison to the actual calibration weight used. See Section 7.1 on page 23 for more information on troubleshooting. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 18: Communication

    BenchPro – Retail Bench Scales Communication This section provides information regarding the connection of the Rice Lake Weighing Systems BenchPro Retail scale. Scale to Computer Port Connections The BenchPro Retail scale can be connected to a computer using a compatible third party software program. In order for the...
  • Page 19: Usb

    USB Specs • Vendor ID = 1C19 • Product ID = 0002 Model Interface Protocols • NCI, SMA, ECR, Auto-1, Auto-2, Print, USB Hid (USB port only) © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 20: Interface Protocols

    BenchPro – Retail Bench Scales Interface Protocols 6.4.1 NCI General Serial Communications Protocol Command W<CR> (57h,0dh) Over capacity <LF> <U> <U> <CR> <LF> <H1> <H2> <CR> <ETX> (invalid data) Under capacity <LF> – – – – – – – – <U>...
  • Page 21: Ecr Interface Protocol

    <CR> <LF> S <H1> <H2> <H3> <CR> <ETX> In lb:oz <LF> <p> <sp> <W> <W> <W> <sp> <W> <W> <CR> <LF> S <H1> <H2> <H3> <CR> <ETX> Table 6-15. Request Displayed Weight © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 22 BenchPro – Retail Bench Scales Command S<CR> (53h,0dh) Command Z<CR> (5ah,0dh) <status> <LF> <H1> <H2> <H3> <CR> <ETX> Simulate ZERO key <LF> <H1> <H2> <H3> <CR> <ETX> Table 6-16. Request Current Status Table 6-17. Request Scale to Zero Command U<CR> (55h,0dh) Simulate UNIT key (lb/oz/kg) <LF>...
  • Page 23: Sma Interface Protocol

    <s> = 'Z' or 'O' or 'U' <LF> <s> <r> <n> <m> <f> – – – – – – – – – – <U> <U> <U> <CR> Table 6-27. Request Displayed Weight After Stability © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 24 BenchPro – Retail Bench Scales Command <LF>Q<CR> (0Ah,51h,0dh) In lb/oz/kg/g (normal data) <LF> <s> <r> <n> <m> <f> <W> <W> <W> <W> <W> <W> <W> <W> <W> <U> <U> <U> <CR> In lb/oz/kg/g <LF> <s> <r> <n> <m> <f> <W> <W> <W> <W> <W> <W> <W>...
  • Page 25 ' ' Scale not in motion <f> Future <U><U><U> Measure units "lb ","oz ","1/o","kg ","g" <W><W><W><W><W> <W><W> Weight data fixed at 10 Bytes <y><y><y><y><y><y> Contain 25 characters maximum Table 6-41. Symbols Used © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 26: Seal Scale For Weights And Measures

    BenchPro – Retail Bench Scales Seal Scale for Weights and Measures Once parameters for the scale have been configured, See Section 4.2.3 on page 8, the scale must be sealed for Weights and Measures. Display Label Position Setup Switch Tamper Plug Access Hole PN 188237 CALIBRATION VOID...
  • Page 27: Maintenance And Troubleshooting

    Loss of power to a USB device or intermittent loss of power to the scale causes the scale to turn off. The display may remain at the last display state. Power cycle the scale to reactivate the display. Load Cell Wiring Figure 7-1. Load Cell Wiring © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 28: Specifications

    BenchPro – Retail Bench Scales Specifications Dynamic Response Response time for stable weight 0–1,000 d, 1,000 ms, maximum mean average 1,000 d +, 1,500 ms, maximum mean average Internal Resolution 500,000 internal count minimum Overload Protection Corner and center overload protection Power In-line Power Supply (included) Input...
  • Page 29: Dimensions

    Table 8-2. BenchPro Options 8.2.1 Column Bracket and Post Option (PN 174783) An optional column bracket is available for use with the remote display (not included). Figure 8-2. Optional Column Bracket and Post © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 30: Tabletop Display Post Option (Pn 183103)

    BenchPro – Retail Bench Scales 8.2.2 Tabletop Display Post Option (PN 183103) An optional 16'' high desktop display mount post is available for use with the remote display (not included). The mounting post has provisions to secure it to a table or counter using the mounting holes and adequate hardware. The remote display attaches to the mounting bracket using two magnets which are included with each display.
  • Page 32 Specifications subject to change without notice. Rice Lake Weighing Systems is an ISO 9001 registered company. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319...

Table of Contents