Packing Maintenance - Emerson Fisher SS-83 Instruction Manual

Angle valve
Table of Contents

Advertisement

Instruction Manual
D102030X012
Figure 1. Fisher SS-83 Valve (Continued)
15A1619-A

Packing Maintenance

Note
For valves with ENVIRO-SEAL live-loaded packing, see the Fisher instruction manual, ENVIRO-SEAL Packing System for Sliding-Stem
Valves, for packing instructions. For valves with HIGH-SEAL live-loaded packing, see the Fisher instruction manual, HIGH-SEAL
Live-Loaded Packing System, for packing instructions.
For spring-loaded single PTFE V-ring packing, the packing spring maintains a sealing force on the packing. If leakage is
noted around the packing follower, check to be sure the shoulder on the packing follower is touching the bonnet. If
the shoulder is not touching the bonnet, tighten the packing flange nuts until the shoulder is against the bonnet. If
leakage cannot be stopped in this manner, proceed to the Replacing Packing procedure.
5-INCH (127 mm) YOKE BOSS
SS-83 Valve
March 2013
5