Instruction Manual
VCIMD-14940
November 2021
Spence Type K3 Control Valve
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
fire and/or chemical contamination
causing property damage and personal
injury or death.
Emerson Control Valve must be
installed, operated and maintained
in accordance with federal, state and
local codes, rules and regulations
and Emerson Process Management
Regulator Technologies, Inc.
(Emerson) instructions.
If the control valve vents gas or a
leak develops in the system, service
to the unit may be required. Failure
to correct trouble could result in a
hazardous condition.
Installation, operation and maintenance
procedures performed by unqualified
personnel may result in improper
adjustment and unsafe operation. Either
condition may result in equipment
damage or personal injury. Only a
qualified person shall install or service
the Type K3 control valve.
Introduction
Scope of the Manual
This manual provides instructions for the installation,
start-up, setting, maintenance, troubleshooting and
parts ordering for Type K3 control valve.
WARNING
Product Description
Type K3 control valve is designed for economical
control of steam, water, gas and process applications
in typical institutional, commercial and industrial
processes. Type K3 is a three-way valve available with
either a direct or reverse acting actuator that meets
most mixing or diverting application requirements.
www.SpenceValve.com
Figure 1. Type K3 Control Valve
Type K3

Advertisement

loading

Summary of Contents for Emerson Spence K3

  • Page 1 Emerson Control Valve must be installed, operated and maintained in accordance with federal, state and local codes, rules and regulations and Emerson Process Management Regulator Technologies, Inc.
  • Page 2 Type K3 Specifications This section lists the specifications for the Type K3. Factory specification are stamped on the nameplate fastened on the control valve at the factory. Control Valve Type Construction Materials Type K3: Three-way valve with union ends and Body: Bronze Seat: Stainless steel pneumatic actuator...
  • Page 3 Type K3 DIVERTING MIXING DIVERTING Figure 3. Fluid Flow Direction for Mixing and Diverting Service Principle of Operation could exceed the limits given in the Specifications section and/or control Type K3 valve is a three-way, universal construction, valve nameplate. globe style, pneumatic diaphragm control valve. The Additionally, physical damage to the pneumatic actuator can be arranged as direct or reverse acting.
  • Page 4 Type K3 UNIFLEX UNION STEAM K3 DIVERTING VALVE TEMPERED SPENCE WATER STEAM TRAP RETURN K3 MIXING VALVE COOL WATER HEAT EXCHANGER Figure 4. Type K3 Control Valve Recommended Installation for Steam Application Planning • Use Uniflex Pipe Coupling for ease of maintenance. The spiral wound gasket provides a high •...
  • Page 5 1/8 in. / 3.18 mm away from to service. Only parts manufactured by actuator stem (key 16). Emerson should be used for repairing this control valve. 3. Disengage lock nut (key 26) from bonnet (key 25). With an adjustable wrench, unscrew valve stem Due to normal wear or damage that may from actuator stem.
  • Page 6 Type K3 Disassembly of the Actuator Lapping Plug into the Seat 1. Remove actuator from the valve. △ CAUTION 2. Remove regular casing bolts (key 4) and casing nuts (key 5). Seats and plugs should never require more than the lightest touch up with very 3.
  • Page 7 Type K3 Replacing the Actuator on the Valve Reverse Acting Body - Pneumatic 1. Apply sufficient air pressure to diaphragm case to start moving the valve through its rated travel. This 1. Put actuator assembly over the valve stem. is shown by the travel indicator (key 32). 2.
  • Page 8 Upper Casing, Steel/powder to service. Only parts manufactured by Springs, Steel Emerson should be used for repairing this Casing Bolt, Standard, 10/14 required, 304 Stainless steel control valve. Casing Nut, 12/16 required, 316 Stainless steel...
  • Page 9 Type K3 Table 2. Type K3 Valve Body Assembly Parts List NPS 1 / NPS 1-1/4 / NPS 1-1/2 / NPS 2 / ITEM PART NAME QUANTITY MATERIAL NPS 1/2 / DN 15 NPS 3/4 / N 20 DN 25 DN 32 DN 40 DN 50...
  • Page 10 Type K3 MIXING DIVERTING UPPER COMMON PORT PORT LOWER PORT MIXING Figure 5. Type K3 Control Valve Assembly Drawing Table 4. Type K3 Actuator Connector Kits K-KIT INCLUDES PART NUMBER SIZE Stem Bolt Bushing Spacer WALKKIT-1 NPS 1/2 to 2 / DN 15 to 50 WAL04-17277-00 WAL04-17278-00 - - - - - - - - - - -...
  • Page 11 Type K3 REVERSE ACTING DIRECT ACTING 05-04841-00 OPTIONAL SPACER #04-17280-00 FOR #60 REV. ACT 10 TO 15 psi Figure 6. Type K3 Actuator Assembly Drawing LOWER CASING BOLT HOLE PISTON SPRING RECESS STEM FLATS Figure 7. Piston Diaphragm Assembly Drawing...
  • Page 12 SpenceValve.com VCIMD-14940 © 2021 Emerson Electric Co. All rights reserved. 11/21 Spence is a mark owned by one of the companies in the Emerson Automation Emerson Automation Solutions Solutions business unit of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co.