Page 3
ALGAS-QA Instruction and Operation Manual NOTES: BIFFI Italia has taken every care in collecting and verifying the documentation contained in this instruction and operating manual. Nevertheless Biffi Italia does not provide any guarantees for this instruction manual. BIFFI Italia will not be responsible for any mistakes contained in it or for any damage either accidental or due to the use of this manual.
1.1.2 Terms and conditions Biffi Italia srl guarantees that all the items produced are free of defects in workmanship and manufacturing materials and meet relevant current specifications, provided they are installed, used and serviced according to the instructions contained in the present manual.
Instruction and Operation Manual Identification plate It is forbidden to modify the information and the marks without previous written authorization by BIFFI Italia S.r.l. The plate fastened on the actuator contains the following information (Figure1). Figure 1 – Data plate Description of the actuator “Algas-QA”...
Page 6
The actuator yoke has a hole with keyways suitable for the assembly of an insert bush or a stem extension. Their internal hole is machined (by BIFFI or at Customer's care), according to the shape and dimensions of the valve stem.
Page 11
ALGAS-QA Instruction and Operation Manual If required, for the standard models size 0.3 to 6, Biffi can supply an insert bush with un-machined bore in accordance with Biffi standard table SCN6202. On request the insert bush bore can be machined by...
Page 12
Insert bush turned upside down Picture 4 – Insert bush + intermediate coupling flange The Biffi insert bush with 2 external keys at 45° allows to position the keyway for the valve every 90°. Consequently actuator can be mounted in 4 positions at 90° on top of the valve. For biggest actuator models, the bore of the yoke can be machined according to the dimensions of valve stem.
Page 14
Any lifting method different from what described above is strictly forbidden. BIFFI reject any responsibility for damages to goods or injuries to persons coming from wrong lifting operations. The actuator can be assembled onto the valve flange either by using the actuator-housing flange with threaded holes, or by the interposition of an adaptor flange or a spool piece.
(Picture 3.4.1). The calibration of the operation time is made by Biffi Italia S.r.L according to customer requirements and to technical data-sheet included in technical documentation.
For this operation it is necessary to disassemble the mechanism cover. In larger actuators the lubrication can be performed through the inspection holes of the cover after removing the plugs. The following grease is used by BIFFI for standard working temperature and suggested for re-lubrication: AEROSHELL GREASE...
Instruction and Operation Manual 8 SPARE PARTS For spare parts order to the relevant BIFFI office please make reference to BIFFI order confirmation concerning all the supply, and serial number of the actuator (Section 1.2) for any specific spare part for a specific actuator model.
Need help?
Do you have a question about the ALGAS-QA Series and is the answer not in the manual?