General Information; Product Description; Uses; Scope Of Delivery - Xylem Sensus Cordonel DN 40 Installation And Operating Instructions Manual

Static flow meter
Table of Contents

Advertisement

1. General information

Please read these instructions carefully and fully before you start installing the meter. Follow all the safety and warning instructions to avoid per-
sonal injury and damage to the meter and the overall installation. Before installing the meter, make sure the delivery is complete and free from
damage.
Intended use
Cordonel meters may only be used for the applications specified in the data sheet and in these operating instructions. Correct and safe use of
the products requires proper transportation, storage, installation, commissioning and operation. The permissible ambient conditions must be
observed at all times. The notes given in these instructions must be followed fully.
Exclusion of liability
The contents of these operating instructions have been checked thoroughly for compliance with the hardware and software described. Neverthe-
less, minor deviations cannot be ruled out due to continuous improvements, meaning Sensus shall assume no liability whatsoever for full compli-
ance. The information in these instructions is checked regularly and any corrections are included in the next edition.

2. Product description

Cordonel is a static bulk water meter for industrial and commercial applications. The meter uses ultrasonic technology based on the transit time
method. The meter is equipped with three ultrasonic paths, which are arranged in pairs and alternately send and receive ultrasonic signals with
and against the direction of flow of the water. The time the signal takes to go from the transmitter to the receiver is measured. The flow velocity is
calculated using the differing transit time of the signal with and against the flow. The flow volume is calculated by multiplying the flow velocity by
the constant cross-section of the measuring tube.

3. Uses

- For measuring potable water up to 50 °C
- For measuring clean process water up to 50 °C
- For measuring water in field irrigation systems
- For controlling industrial processes using the pulse output

4. Scope of delivery

1 water meter, 2 flange gaskets, 1 operating instructions

5. Technical data

Nominal widths
Pressure stage
Connections
Medium
Metrological approval
Potable water approvals
Medium temperature range
Ambient temperature during storage and transportation
Ambient temperature during use
Accuracy class
Protection class
Mechanical environmental conditions
Electromagnetic environmental conditions
Pulse output (optional)
Battery
Display
Radio frequency
Transmitting power
DN 40 ... 300
PN10; PN16
Flanges according to EN1092-2
Water; chemically neutral
DE-19-MI001-PTB008
KTW, DVGW, WRAS, ACS, KIWA
0.1... 70 °C for industrial applications
0.1 ... 50 °C for commercial applications
Normal conditions: -10 °C ... 40 °C
for one week: -40 °C ... 60 °C
-10 °C ... 70 °C (medium must never freeze)
Class 2
IP X8 acc. to DIN EN 60529:2014
Class M2
Class E2
External module; galvanically isolated
2x type D lithium battery
LCD; 2 rows with symbols
Display line 1: 9 digits
Display line 2: 4 digits
433 MHz or 868 MHz
433 MHz: 10 mW
868 MHz: 25 mW
Cordonel
Page 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents