Content ENGLISH User Manual Compliances and Standards Safety Instructions General Description Technical Specifications Product Label Compatibility Sling Application Care Instructions www.humancaregroup.com...
Notice to user/patient in case of serious incident Human Care’s products are continuously Any serious incident that has occurred in rela- being developed and updated to provide our tion to the product, should be reported to the customers with the highest quality.
• Check that the lift is balanced when moving, This product is not a swing. raising and/or lowering the client. If you are using a Human Care lift with telescopic • Make sure no sharp objects are in contact hanger bar, it is important that the bar hooks with the sling.
The colour code is found next to the sling’s label in the shape of a loop. This loop can also be used to The illustration shows the 25130, NSB-500 and NSB-501 properly store or hang the sling. Technical specifications Item Part no.
Back Belt sling Product Label The label on the sling contains the following information: Human Care company logo This way up arrow and marking the centre UP / UPP / OMHOOG / line of the sling OBEN / EN HAUT...
Compatibility Human Care Group slings are designed for use with standard requirements for patient lifts with all Human Care lifts and hanger bars. The as stated in EN ISO 10535. products are also compatible with products of other suppliers utilizing the same attachment...
Back Belt sling Sling Application Applying the sling from a seated position 1. Stand behind or to the side of the patient and hold the sling with the anti slip pad fa- cing the patient’s back. Place the back band around lower back and bring flaps forward under arms.
Page 9
Gait Training 1. Move footplate out of the way to allow for foot steps. 2. Place belt on patient as shown above and lift until patient is in upright position. 3. Hold the sit-to-stand lift steady as you disen- gage the brakes. Remain standing either beside or behind the machine and slow the patient to assume a normal gait.
Correct disposal helps prevent negative Periodic inspection consequences for the environment and human A periodic inspection must be carried out at health. least every 6 months. See Human Care’s peri- odic inspection log which can be found on our website at www.humancaregroup.com www.humancaregroup.com...
Page 11
Dispose of After Use Disinfection Permitted (see list of approved disinfectants) Disinfection Procedure Human Care slings are intended to be used with one patient at a time. To avoid possible trans- mission of infectious diseases, it is important to clean the sling if it has become soiled or if it is to be used by a different patient.
Page 12
HUMAN CARE SWEDEN (HQ) Årstaängsvägen 21B 117 43 Stockholm Phone: +46 8 665 35 00 Fax: +46 8 665 35 10 Email: info.se@humancaregroup.com HUMAN CARE CANADA 10-155 Colonnade Road Ottawa, ON K2E 7K1 Phone: +1 613 723 6734 Fax: +1 613 723 1058 Email: info.ca@humancaregroup.com...
Need help?
Do you have a question about the 25130 and is the answer not in the manual?
Questions and answers