Download Print this page

MAAX OUTLOOK BASE 4836 Quick Start Manual page 2

Outlook shower pans

Advertisement

Available languages

Available languages

Figure 1 - Unit Data and Dimensional Guidelines (Tolerance: +0/ -3 /8 inch)
C
B
C
B
LONG HALF ALCOVE, DEMI-ALCÔVE LONG
MEDIO NICHO LARGO (508)
Helpful Hints for Installation:
C
2 - 5.5" pieces of PVC - These
can be used to lay the product face down
B
and roll it up to the framing pocket rather
than sliding or picking it up.
Please place cardboard from the
carton into the bottom of the shower base
during installation to prevent damage to
the finished surface.
When placing shower base into
the frame pocket, you can use the handle
of the hammer to align the pipe with the
drain hole.
*
These measurements are those of the unit; for easier installation, add 1/4" (6 mm) to dimensions A and B. • Ces dimensions sont celles de l'unité; pour faciliter l'installation,
ajouter 1/4 po (6 mm) aux dimensions A et B. • Estas dimensiones son las de la unidad; para facilitar la instalación, agregar 1/4" (6 mm) a las dimensiones A y B.
ALCOVE , ALCÔVE, NICHO
6"
D
A
Base size / taille de base
48 x 36
60 x 30
60 x 30 R/L
60 x 36
62 x 38
62 1/2" (1588mm)
6"
D
A
NOTE:
D
SHOWER UNITS MAY BE SUBJECT TO
CODE APPROVAL. Refer to job prints
and/or consult with architect to see if your
installation must comply with ADA.
6"
6"
6"
These shower base units install differently
A
from typical residential shower bases.
Installation may need to conform to
D
requirements of the Americans With
A
E
Disabilities Act (ADA) and other local
codes. These requirements relate to the
height of the threshold in relation to the
finished floor. Certain showers bases
will install directly on the sub floor and
ALCOVE , ALCÔVE, NICHO LR/LH
C
B
A
B
48" (1219mm)
37" (940mm)
60" (1524mm)
31" (787mm)
60" (1524mm)
31" (787mm)
60" (1524mm)
37" (940mm)
38 1/4" (972mm)
HALF ALCOVE, DEMI-ALCÔVE, MEDIO NICHO (509)
INSTALLATION
OF
THESE
B
2
6"
D
A
C
D
18" (457mm)
24" (610mm)
15" (381mm)
30" (762mm)
15" (381mm)
8 1/2" (216mm)
18" (457mm)
30" (762mm)
19 1/4" (489mm)
31 1/4" (794mm)
others will require a recess or pit. These
shower bases require special preparation
of the installation site, and very specific
installation procedures to assure the
shower base drains properly and meets
6"
code requirements.
A
D
F

Advertisement

loading