Key Functions - Detecto WPB Series Owner's Manual

Waterproof general bench scale
Table of Contents

Advertisement

This is the Power key. Pressing this key will apply power to the scale and turn it
on. The scale will perform a display test and then change to the weight display.
If the scale is already on, press and hold this key until the display shows
and then release it to turn the scale off.
1. This is the TARE key. It is used to tare (zero) the weight of a container (e.g. a
pan or a box) up to the full capacity of the scale.
2. When setting the Check Weighing upper and lower limits, this key is used to
change to the next digit or setting value.
3. During Configuration, this key is used to advance to the next prompt.
4. To enter Calibration , press and hold this key while powering on the scale.
1. This is the ZERO key. It is used to zero the weight display if the scale is not at
zero. Note that up to a maximum of 2% of the scale capacity can be zeroed.
2. In Weighing Mode, press and hold this key for three (3) to change to an
alternate weighing unit. Repeat this until the desired weighing unit is
displayed (LED turns on).
3. When setting the Check Weighing upper and lower limits, press this key to
begin entering the upper limit set-Hi (SET HI). After entering the upper
limit, press this key to advance to the lower limit setting set-Lo (SET Lo).
Continue this until all limit settings have been entered, and then press this
key to save the settings and return to the weighing mode.
4. During Calibration, this key is used to calibrate the Zero Point weight.
This is the
1. It is used to enable or disable the Check Weighing Function. Press it to
enable the check weighing function. If the function is already enabled,
pressing it will disable the check weighing function.
2. If the Check Weighing Function is enabled, pressing and holding this key
three (3) seconds allows setting the Upper and Lower Limits for the check
weighing function.
3. When setting the upper and lower limits, this key is used to move to the next
digit position of the limit.
4. With the Check Weighing Function disabled, pressing and holding this key
three (3) seconds enables scale Configuration.
5. During Configuration, this key is used to step through the selections when
multiple values are available. For prompts with on and off, or yes and no
selections, it is used to toggle between the selections.
IMPORTANT! Calibrating the scale requires certified test weights, breaking the calibration
seal, and changing the setting of the calibration dip switch. To maintain the high degree of
accuracy, only a qualified technician should calibrate the scale.
8
8525-0380-0M Rev B WPB Series Owner's Manual

KEY FUNCTIONS

CHECK WEIGHING
key. It is used to perform several functions.
,
for
for

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wpb-12Wpb-30Wpb-65

Table of Contents