Detecto solo Operation Manual

Detecto solo Operation Manual

Digital clinical scale
Hide thumbs Also See for solo:

Advertisement

solo
Digital Clinical Scale
Operation Manual
PO BOX 151 x WEBB CITY, MO 64870
0044-0391-0M Rev A
PH (417) 673-4631 x FAX (417) 673-5001
09/15
www.detecto.com
Technical Support: Ph: 866-254-8261 y tech@cardet.com

Advertisement

Table of Contents
loading

Summary of Contents for Detecto solo

  • Page 1 Digital Clinical Scale Operation Manual PO BOX 151 x WEBB CITY, MO 64870 0044-0391-0M Rev A PH (417) 673-4631 x FAX (417) 673-5001 09/15 www.detecto.com Technical Support: Ph: 866-254-8261 y tech@cardet.com...
  • Page 2 8525-M336-O1 Rev A y SlimPRO Operation...
  • Page 3: Table Of Contents

    Before using this scale, read this manual Date of Purchase __________________ and pay special attention to all Purchased From ___________________ "NOTIFICATION" symbols: __________________________________ __________________________________ IMPORTANT ELECTRICAL __________________________________ WARNING RETAIN THIS INFORMATION FOR FUTURE USE 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 4 Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 5: Introduction

    INTRODUCTION Thank you for purchasing our Detecto solo Digital Clinical Scale. Your scale has been designed for simple and straightforward use and to assure accuracy and dependability for years to come. Please read this manual thoroughly before using your scale and keep it handy for future reference.
  • Page 6: Installation

    Display with Upper Outside and Inside Column (pre-assembled) Lower Inside Column Lower Outside Column Scale Platform (with Column Housing Cover) Hardware Pack containing: (4) M5 x 15 Machine Screws (4) Lock Washers (2) M3 x 12 Screws 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 7: Assembly

    1. Align Part 2 (lower inside column) with Part 1 (pre-assembled display upper outside and inside column). 2. Press the parts together until the locking tab snaps in place. 3. Ensure that the locking tab is locked securely. Ensure locking tab is securely locked. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 8 Press locking tab is securely locked. inward to insert Part 2 into Part 3. Install (1) M3 x 12 screw on each Slide the cable side of Part 3. connector through Part 3. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 9 Tighten the screws to secure the column to the scale platform. The scale should be placed on a flat, level hard-surfaced floor or low-cut, unpadded carpet, away from any rapidly moving air source (heating and cooling vents). 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 10: Unit Selection

    Scale will power on. Follow the steps above. BATTERY OPERATION To operate the solo Digital Clinical Scale from batteries, you must first install the included six (6) "AA" size alkaline batteries. Batteries are contained in a battery holder inside the display.
  • Page 11: Low Battery

    (9) minutes. To turn the scale back on, you simply press the “ ” key. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 12: Optional Ac Power Adapter

    The scale is now ready for operation. Optional PD-UKPLUG Optional (UK Plug) PD-EUPLUG (EU Plug) Optional PD-AC (Medical device 9V AC/DC Adapter, includes USA Plug) 9V DC Power Jack 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 13: Operation

    ” key will accept the current displayed setting of the parameter. Second, the “ ” key is used to signal completion of the entry of data (in both setup and operation) and causes the scale to process the data entered. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 14 Mass Index (BMI) calculation. Note that the scale will not respond to pressing the key unless the weight is stable. When using the solo height rod (or no height rod), pressing the key once allows the operator to enter the height of the patient using the © © or ª keys to increment or decrement to the correct height.
  • Page 15: Annunciators

    These annunciators are turned on when the displayed height measurement is in feet and inches. HEIGHT This annunciator is turned on when the scale is in the height measurement mode. WEIGHT This annunciator is turned on when the scale is in the weight only mode. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 16 OPERATION, CONT. Annunciators, Cont. BMI (Body Mass Index) This annunciator is turned on when displaying the calculated Body Mass Index. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 17: Weighing Mode

    8. To turn scale off, press the “ ” key. If the Automatic Shutdown feature has been enable, the scale will turn off after a pre- defined time of inactivity (no motion or weight on scale). 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 18: Height And/Or Bmi Measure Mode

    OPERATION, CONT. Height and/or BMI Measure Mode (using solo Height Rod or no Height Rod) 1. Assist patient onto scale. 2. The display will show the patient’s weight. 3. Read and record weight displayed. 4. Press the “ ” key to enter the Height mode.
  • Page 19: Solo Height Rod Operation

    9. Lower headpiece back to vertical position and return height rod to the “stored” position (headpiece should be vertical against outer column and height rod display cover should be flush with the display). 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 20: Setup

    SETUP Your solo Digital Clinical Scale has been pre-configured at the factory and should not require changes for use in most applications. However, if the factory settings do not meet the requirements of your operation, the following describes the setup process for your scale.
  • Page 21 NOTE: The default Buzzer setting is 1 (enable). Setup Complete Once the “ ” key has been pressed at the 2<gg prompt, all Setup settings (current or new values) will be saved and the scale will turn off. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 22: Calibration

    CALIBRATION Your solo Digital Clinical Scale was calibrated at the factory and should not require adjustment. In the event that the scale should need re-calibration, the following describes the calibration procedure. To maintain the instrument’s high degree of accuracy, a qualified technician should perform this function.
  • Page 23 Step 12. When reading is stable, the second weight reading will be saved. Step 13. The display will change to show $** and then automatically shut the scale off. Step 14. The scale is now ready for operation. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 24: Serial Data Format

    SERIAL DATA FORMAT The serial port on the solo Digital Clinical Scale is a bi-directional port and can receive and transmit data. It can be used to communicate to a computer by to pressing the “ ” key or transmitting a command to the scale.
  • Page 25: Display Messages

    DISPLAY MESSAGES The solo Digital Clinical Scale is equipped with software that tests various portions of the scale's circuitry and verifies proper operation. Should a problem be detected, a message will be displayed alerting the operator to that condition. The following lists the messages...
  • Page 26: Care And Cleaning

    DO remove power before cleaning with a damp cloth. x DO provide clean AC power and adequate protection against lightning damage. x DO keep the surroundings clear to provide clean and adequate air circulation. 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 27 0044-0391-0M Rev A y solo Digital Clinical Scale...
  • Page 28 0044-0391-0M Rev A y solo Digital Clinical Scale P/N: 700352273(Rev. 15.11)

Table of Contents